Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Aussie Dave

    Wooden fence retaining wall

    Hi All, I am currently working on a wooden fence post retaining wall solution designed by an Architect attached. I have been asked to calculate the attached, the problem is that I have calculated sheet piling using Gross Pressure Method in the past, but I am not sure if I can calculate the...
  2. Aussie Dave

    Wind allowances for workshops and large buildings

    I am currently working on a large workshop with two roller door openings either end of the building; this workshop is located in England East Anglia. Does anyone have guidance on appropriate wind allowances for large workshops and buildings, I think a figure of 1.5KN/m^2 can be used?
  3. Aussie Dave

    Plinth wall help

    Hi fellow Engineers, Please see attached strip foundation with Plinth design. My problem is that I have never done a plinth wall design before only cavity walls etc. Can I place my cavity wall central to strip foundation as per normal ignoring Plinth? or do I need to add eccentricity to the...
  4. Aussie Dave

    Projection past plinth wall on strip foundation

    Hi All, The problem I have is that the foundation calculations prove that a 600 x 225mm strip foundation will be sufficient to take loads of the build in concern, but in the NHBC the minimum projection is 150mm, but The plinth wall I have is 360mm in total leaving me with 120mm projection will...
  5. Aussie Dave

    Ground Bearing Slab calculations to TR34

    Hi all, I have been been working to TR34 4 Edtion please find attached calculations. I have found that I have a higher positive load rather than a negative load in my moment's calculations and on other examples that I have been following they always have a higher positive moment for ground...
  6. Aussie Dave

    Ground bearing garage floor with medium to high heave potential

    On a job I am working there is a number of garages that need to be built. The site has a clay soil with a medium-high volume change potential between 100-150mm and the ground bearing strength of the soil is 80-100KN/m^2. I was going to design a ground bearing slab 150mm thick with 150mm sub...
  7. Aussie Dave

    Slabs on Grade using simply supported two-way slab formula

    Hi All, would it be sufficient to use below calculations for a slab supported on grade? I am working to book (Reinforced Concrete Design to Eurocodes Design Theory and Examples Fourth Edition) simply supported two-way slab: Corners free to lift * Design of moment reinforcement * Shear...
  8. Aussie Dave

    Slab on grade

    Hi All, I have a reinforced concrete slab with 50mm cover A393 mesh 10mm bars and the dimension are 6.19 x 3.031 and 150mm thick. This slab is going to have 150mm of grade under slab. Does anyone know the best design approach to take? I have been using EC2 codes, but I can only find simply...
  9. Aussie Dave

    Live loading Standards

    Hi All, I have been looking at the different live loads on a domestic house. Is it appropriate to use 1.5UDL as stated in BS 6399: 1996 or should I use the slightly higher load of 2 KN/m^2 as indicated in building regulations Approved Document A Table 4 ?
  10. Aussie Dave

    Domestic Light block and metal stud partitions on the plan

    Hi All, in the regulations permanent partitions shown on the floor plans should be considered as dead load and flexible partitions which may be movable should be allowed for in the imposed loads, with a minimum of 1KN/m^2. I have been looking over some foundation calculations for domestic...
  11. Aussie Dave

    Strip foundation depth

    Hello I have a question regarding strip foundations according to the NHBC a strip foundation minimum thickness should be equal to the projection 150mm and the depth of the foundation should be equal to the projection. This is to allow for the stress that works at 45 degree angles, but I have...
  12. Aussie Dave

    Foundation Design

    Hi All, I have a two story house seperated by a party wall and I am working out the foundation sizes for the properties before they are built. I have a ground bearing strength of 100KN/m^2, so I have calculated the party wall to be taking a load of 60kN/m^2 on either side of the party wall. Does...

Part and Inventory Search