Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: MAB70
  • Content: Threads
  • Order by date
  1. MAB70

    When to Consider Seismic Loads on Columns in Shear Wall-Dominant Designs?

    Hello everyone, I’m working on a building where shear walls are the primary lateral force-resisting system for seismic loads. My goal is to let the shear walls handle most, if not all, of the lateral load, potentially reducing seismic design requirements on the columns. I’m aware that Eurocode...
  2. MAB70

    Hollowcore Slab Ties in Topping Vs Grouted in HCS

    Hi all, If i am planning to have a 75 mm topping above my hollowcore slabs for diaphragm, do i still need to include ties within the hollowcore slab itself? or just provide ties in the topping? Do i need to breakout the cores and grout with ties as per the picture below? or this would be an...
  3. MAB70

    Seismic Resonance Impact on Buildings

    Does anyone know how does the Code addresses resonance of seismic against buildings? I understand that ground motion is complex but theoretically you dont want the seismic period to match the building natural period. How do we check that or how does the code address that? Specially that...
  4. MAB70

    Seismic Force Percentage for Dual System, Building Frame System and Shear Wall Frame Interaction

    Hi all, I have three question with regards the lateral resisting systems in the ASCE7; 1. When you use dual system of moment frames, it says to be capable of resisting 25% does that mean it doesn't necessarily need to have enough stiffness to attract 25% of the load and only as long as its...
  5. MAB70

    Drained Cavity Water Protection in Deep Basements - Diaphragm Wall Leakage

    Hi all, We are working on a project (as advisory role) where we have 6 underground basement which will be used purely for car parking. The client requirement is a grade 1 basement as per BS8102 which allows damp patches and seepage, however the consultant due to the deep excavation, he...
  6. MAB70

    Locally Embeded Steel Sections Inside Concrete Columns (Design)

    Hi Everyone, I have a reinforced concrete tower that requires locally a cantilever mezzanine in one of the floors. We had to propose the mezzanine to be in steel for its light weight and additional strength. To get rid of the complicated connection of anchors to concrete columns we are...
  7. MAB70

    Bonded Post tension slab Cracking due to restraint of Stiff Vertical Elements

    I am new in PT design and a bit confused on the reasons of cracks due to restraint of stiff vertical elements in post-tension, My questions are: 1. Are the cracks a result of loss of pre-compression in the slab and diverted back to the vertical elements?or is just restraint due to drying...
  8. MAB70

    Shear Lug Breakout Failure When Force is Parallel to the Edge

    Hi all, I am connecting a steel beam to a concrete column and having a shear lug to take the huge shear forces from gravity loadings. I am designing the shear lug as per ACI 349, the code does not discuss the checks of the shear lug incase the force is parallel to the edge (not...
  9. MAB70

    When does RC serviceability limits directly affects strength of an element ?

    I am currently working on a project for structural assessment of an existing 3-underground story car parking building. The system of the slabs are solid slabs of 160 mm thick spanning two way of 8.6 m C/C on shallow RC beams. The slab deflections and vibrations by calculation and what is...

Part and Inventory Search