Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: T2ioTD
  • Content: Threads
  • Order by date
  1. T2ioTD

    Meyerhof Point Bearing Capacity - The Limiting Factor

    I am troubled with the so called Meyerhof limiting factor for the point bearing capacity, which always seems to be much lower than the formula it intends to control, up to making the main formula completely obsolete- either this, or I miss something completely. First, some extract from Braja...
  2. T2ioTD

    Are anodes always wired back to the steel in the case of passive cathodic protection?

    My question if for galvanic systems only (not immersed). Pardon my ignorance, but in the first image, the theory dictates an insulated wire back from the sacrificial anode to the tank, while in the second image, the anodes seems directly welded to the tank, visibly by a conducting metal, and...
  3. T2ioTD

    Steel bolted tank above concrete raft on piles - Is cathodic protection mandatory? Where exactly?

    I'm filling some technical papers for a bid, and my boss, who is a mechanical engineer, insists no cathodic protection is required for a steel water tank above concrete pad (I designed the pad myself, and the water is for firefighting purposes). Another mechanical engineer said only the tank...
  4. T2ioTD

    Shear Wall Design - Model With or Without Piles as springs?

    By believing I should seek precision in my model (20 story building with small floor area), I opened a pandora box and I don't know how to proceed. I know the majority model their superstructure with supports as pinned/fixed even if there are piles beneath, but I figured out that maybe by...
  5. T2ioTD

    Please help clarify those Post Tension concepts

    Please help clarify those Post Tension concepts I have a couple of questions regarding post tension slabs, and though I'm reading and playing with FEM software, they elude me. 1. Balancing x percent of the dead load means cancelling x percent of the deflection due to the dead load? But...
  6. T2ioTD

    Connecting a rafter to a shell

    I couldn't find any reference but a tiny one (I will mention it at the end of this text) about how to derive the stress (even an approximation of it) of a shell under a point load acting along its surface. For instance: checking whether the loads exerted by a rafter attached to a shell is...
  7. T2ioTD

    Any ressource to design a bolted water storage tank?

    I noticed that API 650 offers two methods for determining the shell thickness, as well as a method to determine the wind stiffeners. On the other hand, API 12B offers pre-determined tank sizes without any talk about wind stiffeners or anchors to the foundation, and the AWWA-d103 only offers...
  8. T2ioTD

    Are the rafters connected to the crown ring have their moments released at both ends?

    I modeled a tank roof using the SAP2000 software. The roof plates were modeled as loads (not actual shells) and after running the analysis I found the model would only be stable if the rafters have one of their ends not released (logical) but I am not sure if it is the crown ring side that need...
  9. T2ioTD

    Should FEM results be compared to original pile capacity or after efficiency deductions?

    Out of 45 piles, there are like less than 10 which exceed the original (Pile Capacity x Efficiency) but not the Pile Capacity itself. Is this ok?
  10. T2ioTD

    About the design of purlins cleat

    I am new to steel design. In some FEM software (Autodesk Robot) many steel connections are offered, but not the connection between a purlin and a rafter. I googled the purlins cleat on the web, and I got manufacturers offering their products without listing the strength properties. So my...
  11. T2ioTD

    If a water tank is not anchored, then should the foundations exeperience any seismic effect?

    I'm studying an API650 water tank, and this is the first time for me. I'm studying the foundations too, and after finishing doing an excel spreadsheet with all the calculations proposed by API650, I do not know whether (and how) to load the earthquake moment over the foundation, especially as my...
  12. T2ioTD

    When a soil report mentions cohesion C, do you assume it is undrained or drained?

    I've never read a soil report where a distinction is given between a Cu and C'. Is there some consensus that the C value they give is one or another? (I have read many reports from Iraq and Lebanon). I should also mention that triaxial tests are commonly not done in these countries, and C...
  13. T2ioTD

    When designing a raft foundation on piles, does the soil under the raft contribute?

    When designing a raft foundation on piles, does the soil under the raft contribute to the load bearing capacity? What if the the piles are assumed to take 70 percent of the load and the raft the remaining 30, but in reality the settlement is different between these two parts?
  14. T2ioTD

    Eurocode Wind Coefficients (a basic question)

    In Eurocode Wind load code, for cylindrical shapes for example, why do we have (1) pressure coefficients vs (2) force coefficients? Are the pressure coefficients to input in FEM software, while the force coefficients for a direct (manual) calculation of the resultant force? Suppose an engineer...
  15. T2ioTD

    About the roof of an API 650 tank

    I have difficulties understanding technical matters regarding a self supported (no middle columns) roof for an API water tank. 1. The excel sheet on the right shows 6mm thickness for the roof. I assume it is because no rafter are being used, otherwise thickness would be around 2mm. Am I right...
  16. T2ioTD

    How to give stability to a simple shed in the pinned direction?

    I am new to steel design, I have background in reinforced concrete and geotechnic. I am studying a simple shed in Robot software. Since there is no connection that will transfer a moment between a beam and the WEB of a I column (red beams in the y direction with the yellow columns) I had to...
  17. T2ioTD

    Is Modal Analyisis really needed for UBC97 (or other) Seismic Equivalent Static Methods?

    I watched a video performing a preliminary check for the general building deformation for the UBC97 seismic equivalent static method, then he goes on, in the next video, and adds the modal load, and proceeds with his equivalent static method study, as we all know. I am confused here: How could...
  18. T2ioTD

    Is it possible (or common) to attach a tricone to a solid stem auger? And other tools questions.

    I have some background in shoring design, but never was able to study closely technical operations. I hope to get some answers for my questions below: 1. Is it possible (or common) to attach a tricone drilling head to a solid stem auger? Or are the claw bit the only available option? 2. Is it...
  19. T2ioTD

    Isn't the clear cover of 4 cm that is required by ACI for columns excessive?

    I find a clear of 4 cm for columns too much: often residential columns are narrow to fit into wall partitions (at least in the middle east), and taking 4cm + ties diameter from the effective depth will leave the column weaker and requiring more and more steel. In Eurocode the normal clear cover...
  20. T2ioTD

    Has any Etabs 19 user noticed these glitches in the program?

    Hi I like Etabs better than Robot, because of the speed I can go from analysis to design and backwards without waiting for new environments to open up... However, I noticed some misbehavior in Etabs 19: 1. I have to fight (and often lose) for the right to assign the 'View/Revise Punching Check...