Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: JohnTerry4
  • Content: Threads
  • Order by date
  1. JohnTerry4

    Tallest Cantilevered Soldier Pile Wall

    I am wondering if anyone has experience with cantilevered soldier pile walls exceeding 30 feet for a site where Moderate rock is pretty much fully on the active and passive sides. Analysis indicates that moments, shear, and deflections are under control; but I am having second thoughts because...
  2. JohnTerry4

    Heelblock on Organic Soils

    I am wondering if anyone has ever experienced a project where a heelblock must be placed on a very soft organics stratum. Tie-backs are not an option here. What is recommended here? Support the heelblocks on helical piles? Has anyone ever just placed the heelblocks on the organics, since this...
  3. JohnTerry4

    Stormwater System within New Building Footprint: Effects on Foundations

    I have a client who is looking to construct a building to the property lines and wants to construct an open-bottom recharge chamber below the lowest floor level. Besides ensuring the ground has a sufficient permeability rate, are there any other geotechnical concerns from dumping stormwater near...
  4. JohnTerry4

    Growing a Recently started Business

    I started my geotechnical consulting company three years ago. I have gotten decent growth, but looking to step things up in terms of building a strong clientele, increasing revenue, and hiring employees; but cannot figure out how. What are some steps one can take to grow company exposure, earn...
  5. JohnTerry4

    Underpinning Concern

    We have a townhouse building that is being underpinned to lower the cellar slab by approximately 4 feet. The existing footing is a stone footing that protrudes into the building by 12-inches. Therefore, Owner is concerned that underpinning will reduce cellar width by 12-inches on each side, so...
  6. JohnTerry4

    Accounting Software

    Does anyone have any highly recommended and comprehensive accounting software for a very small engineering consulting firm with?
  7. JohnTerry4

    LVL Beam Reinforced by Steel Plate

    Hello, I have a 5.25" x 11.875" LVL beam that is spanning 18 feet that was installed at a project but it is not sufficiently sized to carry the bending forces from the weight above. Therefore, I am considering adding a steel plate to the bottom of the beam as a reinforcement measure, and...
  8. JohnTerry4

    Structural Backfill

    Hello, I am wondering if anyone has experience utilizing structural backfill for a retaining wall? Is it reliable, effective in draining water, etc.? I heard about it from block manufacturers and the system is incorporated in design programs. Here is the design mix: 1. SPECIFICATIONS 1.1...
  9. JohnTerry4

    Waterproofing system for an underpinned building

    Hello, I have a building that its 1st floor slab will be demolished and then 8 feet of soil will be excavated so that the building will have a cellar level. Issue is that the existing footings are rubble (not water-resistant obviously) and these rubble footings will be the new cellar...