Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Quade999
  • Content: Threads
  • Order by date
  1. Quade999

    AASHTO Bridge Deck Overhang Design Forces Question for Post and Beam Railing

    Hello, I'm unsure of how to interpret the design forces for the bridge deck overhang. It says to design for the transverse or vertical forces from the impact table (Design Cases 1 and 2). But it also has a section about calculating the forces based off of the railpost capacity (but it also says...
  2. Quade999

    Interpretation of 2 Design Trucks Load Case in AASHTO

    Hello, AASHTO has a clause where you consider 2 design trucks at 90% weight with a spacing of 50 feet between them for negative moment and reaction at interior piers. When they say reaction at interior piers do they mean to include the bearing in this case as well? It just mentions the piers...
  3. Quade999

    Area Enclosed by Shear Flow Path for an I-girder

    Hi, I'm unsure how to calculate the area enclosed by the shear flow path for a concrete I-girder. Would this just be the area of the girder itself?
  4. Quade999

    Composite Steel Girder Force Determination

    Hi Everyone, For determining the forces in a steel girder section with a concrete deck from a modelling program under different conditions, is my interpretation below correct? Before the deck hardens, all these forces are assumed taken by the girder only and is modelled as just the girder...
  5. Quade999

    Unbraced Length Determination at Connection

    Hi Everyone, If I have a connection at a gusset plate as shown below, where the entire connection is welded, would the unbraced length of the bottom member be Unbraced Length 1 or 2? I would assume the connection would help prevent some out of plane buckling. Thanks
  6. Quade999

    Retaining wall with a varying sections. How far to extend upper rebar?

    If I am designing a retaining like shown below, how far should I extend the upper layer of rebar into bottom section to ensure adequate development and load transfer between the tension steel in the two sections? Would 2 times the development length be required? Thanks
  7. Quade999

    Non-Contact Splices Placed Vertically

    Hi Everyone, Design Codes allow a non-contact lap splice of up to 6". Would there be any issue by having a non-contact splice take place vertically instead of transversely like shown below? Provided that the section capacity is calculated assuming the steel is of the lower depth/
  8. Quade999

    Reinforcement Splicing: Any Issues With This Layout?

    Hi Everyone, Due to the existing conditions the reinforcement needs to be spliced as shown below. Is there any issue with the splices looking like this. I don't think so, since all the lap lengths are adequate for full development, but just wanted an outside opinion. Thanks
  9. Quade999

    Flexural Resistance using Skewed Reinforcement

    Hi Everyone, When using skewed reinforcing to calculate flexural capacity the codes don't really give a guideline about taking into effect the skew of bars. I'm assuming you can look at the problem using basic Trigonometry in the example below. Would the assumption be correct that if I am...
  10. Quade999

    Do transverse bars placed at an angle other than 90 degrees affect splice lengths?

    Hi Everyone, If I have a longitudinal layer and a transverse layer of bars that are not 90 degrees to one another, does it affect the required splice length. In the first picture below any affect of the bars 90 degrees to one another is ignored, but what about the situation in the second...
  11. Quade999

    Beam Splice Stagger Distance

    Hi Everyone, Is there a minimum recommended distance that a splice should be staggered away from a developing bar in a beam so that they don't interact with each other. The development length is based off the center to center distance between developing bars, so maximizing this number is ideal...
  12. Quade999

    Code Clarification CHBDC Shear

    Hello Everyone, I'm looking for clarification on the clause below. From what I take is that this clause only applies if my ultimate shear exceeds my concrete shear resistance. The only thing that threw me off is that the clause provides a maximum value for Vc. If you calculate the shear...
  13. Quade999

    AASHTO Calculation of Maximum Reinforcement Spacing Under Service Loads Question

    Hello, In AASHTO under service loads, the reinforcement is required to be spaced less than that calculated using the following equation. When using two layers of tension reinforcement, both reinforcing layers will contribute to the resistance of the section as shown below. From what I...
  14. Quade999

    Question About Allowable Fatigue Stress at a Section with a Splice According to AASHTO

    Hi Everyone, AASHTO doesn't seem to specify the allowable fatigue stress range on a lap spliced section. They only provide information for straight reinforcing bars, prestress tendons, and welded or mechanical splices. See screengrabs below. So my assumption is that a section with lap splices...
  15. Quade999

    Tension vs. Compression Splices

    Hi Everyone, When using high strength steel reinforcing bars (100ksi yield strength), the compression splice length will actually be larger than the tension splice length. My question is, if I have a situation like shown below, where the region of a slab will cycle through positive and negative...
  16. Quade999

    Box Culvert Shear Under more than 2ft of Fill

    Hi Everyone, Is anyone here familiar with AASHTO's provision for the calculation of shear capacity for box culvert slab when under more than 2ft of fill? I've attached the relevant parts below. The wording in Section 5.12.7.3 isn't explicit, but my assumption is that this equation can be...
  17. Quade999

    Double Cell Box Culvert Support Conditions

    Hi Everyone, When analyzing a box culvert I know the trend is to apply an equal but opposite upwards force on the bottom slab to model the reaction of the downwards forces and to place a pin support below the walls. (The assumption is that the soil below provides a uniform reaction force). For...
  18. Quade999

    Lap Splice Fatigue Capacity

    Hi Everyone, Is the fatigue resistance of a contact lap splice the same as that of a continuous bar? I've only seen any differences for a splice fatigue resistance with respect to welded or mechanical splices, which leads me to believe it is the same, but am not 100% sure about the contact lap...
  19. Quade999

    Fatigue Analysis Question

    Hi Everyone, When calculating the stress range for fatigue under live loading I've seen different ways that people do this when the section goes from positive bending to negative bending under passage of the load. For this example, lets say the bottom layer of steel is the one under...
  20. Quade999

    Live Load Surcharge Lateral Pressure Coefficient

    Hi Everyone, I'm not sure which coefficient of lateral earth pressure to use when I have a situation like the one shown below. When you have a live load near a wall, we have to include a horizontal live load surcharge on the wall. If I had the case like shown above where the live load is on...

Part and Inventory Search