Working on a small project that has a fire pump. Instead of conducting a new flow test at the hydrant that is feed from the fire pump it was suggested to use the annual fire pump test. I’m trying to remember how to do that since it’s been years. Can someone help me out?
I have a light hazard building with Dry wall, 12" bar joists, with 6" of batt insulation on the dry wall and then a wood floor for above. So 6" of dead space above the insulation to the underside of the floor. Would this be considered Combustible Concealed space?
Thanks
Looking for some insight on this. We have a 16' high storage facility with metal products being stored. Looking at Figure 16.2.1.3.2b with high temp heads which brings the density to .325 over 2000. i am locking to apply figure 16.2.1.3.4.1 and I want to make sure I am right on this. It would...
Hello all. New guy at this so please be kind. Looking at doing a 13d system for a house. Trying to figure out how calf the system with a home tank. I’m looking a flowing 2 sprinklers at the rates GPM needed. I also have a flow test. But do I use the flow test and the pump together? Or do I start...
Hi all, hoping someone can help me out. I have been asked to look at a daycare facility that is needing a fire sprinkler system. The facility is only a few thousand sqft but they are being required to have fire sprinklers. The main problem is that there is only a 1" domestic line coming into the...
Looking at a building that has vinyl window parts on moveable metal racks stored 16' high at the highest. Right now they have ELO231 sprinklers installed but no hydraulic plaquard. Trying to figure out what density they are using.
Looking at a tiny warehouse that has storage at 15' with building height at 20' Class I commodity on double row racks 15' high. If I use NFPA 16.2.1.3.2 (a) and point E it gives me a .29 over 2000 sq ft. And if I use the density reduction on 16.2.1.3.1 I can reduce the density to 60% which I am...
I have a buddy of mine looking at a decent size warehouse. Its 41' to the deck and they are looking to store Uhaul Uboxes. Which are wood boxes for people to store their stuff in and they look like little sheds. They will probably be stored at 28' high in this open warehouse. If I look at the...
So I am trying to figure out what size fire pump I need. I have a guy that is storing tires and insurance is calling for k25 at 75 psi. My flow test is 162 psi 110 psi @ 1653 gpm. Newbie here just need a little help.
Thanks
Looking at a job that will have 16' high double racks 8' aisles with building materials which include asphalt shingles, windows and of course vinyl siding. Im looking through NFPA and cant seem to find the vinyl siding. I am assuming that would be Group A plastics. Any help would be great.
Thanks
I have a situation where the architect does not want sprinklers to penetrate the cloud. The bottom of concrete deck is 12' and they want the clouds at 11'. Now there are concrete beams that hold up the deck and those are bottom 10'. Wanted to know how you guys handled this? If you can see the...
So the local fire department told us that a building that we usually would not have any standpipes or hose valves needs them now. They came up with adding 5 hose valves per floor. There are 3 floors. Each floor will have a single riser that comes up and a main that runs to each hose valve. When...
Hello,
I am a student learning fire sprinklers. We have a project involving a four story building that is existing. They are calling for just sprinklers at the windows for protection near the fire escape. Can I use regular standard fire sprinklers? Each floor consist of 5 windows that will need...