Does anyone have experience with a vertical Sundyne LMV-801 with an intermediate bearing box between the motor and the pump?
We have a pair of 15 HP pumps that have experienced repeat bearing failures even after factory troubleshooting. Pumps are high suction pressure (~400 PSIG) and typically...
Hey guys,
I've been having trouble with a pair of Sundyne LMV 311s and I'm running out of troubleshooting ideas. Figured I'd ask around to see if anyone has had similar issues or has any suggestions.
Background:
The pumps move ambient temperature light hydrocarbons at a low flow (cycles...
Hey guys,
I'm running out of troubleshooting ideas with on a particular GE vertical motor so I figured I'd give the forum a shot.
The issue we're having is on a 150HP, 2 pole, 2300V GE vertical motor. This is driving a 9 stage vertical turbine LPG pump. No VFD, just an across the line starter...
Hey Guys,
Figured I'd give this forum a shot since this particular problem has us really baffled.