Hello All,
I need your insight.
We are building a process tank that is designed to API650.
By process, I mean it is not a simple storage API 650 tank and there is many internal plates (kick plates, deflectors etc.) inside tank that are welded to shell for a its process requirements.
Some...
Hi Folks,
We are in process of hydro testing an API 650 tank, cylindrical design, 12.5-m H x 39-m DIA.
The tank has multiple chambers that are isolated from each other, imagine now one big wall of 10-m Height separating the tank into two compartments.