Hello guys,
i have a linear hydraulic cylinder controlled by a plc through 4-20 mA proportional valve.
The whole hydraulic system composed of:
- proportional valve.
- blocking valve.
- pressure switch " to ensure oil presence"
- a position transducer.
when trying to move the cylinder up/down it...
Hello guys
i have a network f G120C PN drives connected via Profinet cables to an ET200SP plc.
i already have the project of the drives created by Starter software and is saved in my pc knowing that the drives are in factory settings.
how to proceed to download the project to the drives ? is...
Hello guys,
i need help please, i have a Beckhoff BC9050 PLC connected to Proface HMI.
i connected to the controller through TwinCat 2 but can't upload the whole program.
do i need to install the OPC server in my pc to have access to the whole program ?
if so which version do i need ?
Thanks in...
Help Request
Hello Guys
i have a Sinamics G120C PN error, when trying to execute the Start Command through the Starter software it gives the following error Message: "the switch-on disable of the drive is active " in addition to this, the diagnostic buffer shows that there is a missing enables...
Hello Team,
i have a Danfoss ETS 25 34G4203 valve with 12V DC located 20 meters away from the EKC 316A Controller, and the cable is only 8 meters length,
in addition to this i have a cable filter AKA 211.
Can i use a shielded cable of 20 meters instead of the original cable ?
Hello guys,
i have to connect a generator of 1125 KVA of 400 V line to line 50 Hz frequency with an Automatic Transfer switch.
the ATS is located 15 meters away from the generator, the company that made the conception of the project implies that we have to use a cable of 12 x (1x300 ) + 4x...
Hello Guys,
please i need help, i have a balance " Commander-N CE care weighting system" with it's printer inside a panel,
my question is:
- wich type of the signal sent from the weighting cells board to the printer ?.
- i have the length of the cable about 8 meters with cable section of 4x0.35...
Hello guys,
i have a 15 KW three phase motor situaded at about 600 meters away from the power source, which cable section do i need to use ?
thanks in advance
Hello guys,
could you please guide me to remove TIA PORTAL V13 Completely from my pc ,
i uninstalled it through the control panel, but it still exist within the programs.
thanks in advance
Hello guys,
Please i need help about SEW Servo drive controlled via SBus & Field Bus Modicon M340 PLC.
The problem is, when the motor reaches its desired position, the homming request still be on and the status word.0 ( motor is turning ) is sent to plc in a flashing manner (On/Off).
What could...