  1. IOC-AUS

    Tech Explanation on Diesel Engine in AC Generator Set

    Hello All, I was hoping to get a Technical Explanation on the Power ( kW Input ) requirements of an Industrial Diesel Engine 1500rpm in a 4 Pole AC Generator Set. Is there any impact on kW Rating ( or another way to ask kW Efficiency ) of a Diesel Engine when the Output Supply and AC Alternator...
  2. IOC-AUS

    Failure of ISO PumpEnd ( Diesel Driven )

    Hello All, We have seen a couple of Broken Pump Shafts ( Stainless Steel ) on Diesel Driven ISO PumpEnds. These are coupled via a 'Close Coupling' arrangement ( ie. Direct Pre-Load Bearing Adaptor with Muff Coupling between Pump & Engine ). I attach a couple of Photos to help show the Failures...
  3. IOC-AUS

    Exciter Stator Failure - Cause ???

    Hello All, Just trying to get an idea of a cause of failure on an AC Generator ( 125 kVA ). See photo - this is the Exciter Stator. The AVR had also blown on this machine. The Generator Set is a Diesel Driven Unit Powering an Electric Pump Motor 55 kW with VSD / Soft Starter. I welcome any...
  4. IOC-AUS

    Diesel Driven Water Pump with Vacuum Priming System - Centrifugal Clutch Engagement Speed

    Hello All, We are Building a Diesel Engine Driven Water Pump System that includes a Vscuum Priming Kit. The Unit needs Remote Start/Stop & Telemetry. We have fitted a Centrifugal Clutch to disengage Water Pump for first 5 minutes so Water Pump can be Primed before engagement. The Priming is...
  5. IOC-AUS

    Sheared Flywheel Bolts on Generator

    Hello All, We recently had a Generator Failure - High Tensile Flywheel Bolts were sheared on the AC Generator. The Generator Set has been in operation and we understand the system includes Solar. My question is could this Generator Failure be caused from incorrect Synchronisation. I would...
  6. IOC-AUS

    Technical Information when Starting Electric Pump Motor

    Hello All, I am new to the forum and joined to see if I can learn more about calculating Technical Data when Starting Electric Motors on Water Pump systems. Have been exposed to various Starting methods including DOL (generally LRC is 6x times FLC) and VSD / Soft Starters (Changing Frequency/...