Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: daren12
  • Content: Threads
  • Order by date
  1. daren12

    Maximum Hydro test pressure per NBIC Part 3, 4.4.2(1)(a)

    Hi all quick question. We have a pressure vessel which falls under alteration. Long story short we hydro tested it to ASME code UG-99(b)and not NBIC Part 3, 4.4.2(1)(a). I am trying to interpret the paragraph 4.4.2(1)(a) which states: "A pressure test as required by the original code of...
  2. daren12

    Adding unlisted materials per B31.3 para323.1.2

    Hi, I am being supplied a 10NPS class 300# RF weld neck flange made from F61 SA-182 UNS32550. Looking trough the code I can see the material is listed in SA182, Section II Part A. However it is not listed in Section II Part D or B16.5 2020 Edition. The assembly will be registered as a H...