I'm using Abaqus/CAE for pre-processing and find that same element type(ex. C3D8R) can have two different element library options(Standard/Explicit).
Curious that if it can affect the simulation results with different options? If I'm running Explicit solver but chose the element with standard...
Hello,
I’m a junior FEA engineer working for phone products. Most of the time, I do dynamic simulations like drop by Abaqus and extract peak stress of parts like display and judge failure risk.
Speaking to extract peak stress, some of my colleagues choose max nodal stress in report, others may...