  1. Delmarva_Struct

    Weld Group With Different Sized Welds

    I have a 2" plate that is sitting on (2) W10x15 beams. The plate is welded ( by the contractor) to the flanges of the W10x15 with a rectangular line weld 3/8" all around. Considering that the thickness of the W10x15 flange is 0.27", my understanding is that on one side the weld can be no more...
  2. Delmarva_Struct

    Wind Uplift Forces on Cold Storage Roof

    For an enclosed building, the wind uplift force on a roof is caused by difference of pressures above and below the roof membrane. The motion of the wind blowing over the roof creates a area of low pressure and the air under the roof membrane is at a higher pressure and so the wind tries to move...
  3. Delmarva_Struct

    Wall Footing Design for Lateral Seismic Forces

    Please see the wall footing snip attached. I have a 450 kip lateral force at the top of the wall which is about 23 ft high and 10 inches thick and 39ft long. This is a non-load-bearing wall and the wall self is the only thing I have to resist overturning as well as sliding. The footing is...
  4. Delmarva_Struct

    Seismic Design of Condenser Unit Supporting Steel Structure - NonBuilding structure

    I am required to design a condenser supporting steel structure for seismic loads. It will consists of 4 steel columns and tension only x bracing between the columns. There will be a network of beams connecting the columns at the top, thus forming a platform on which the condenser unit will be...
  5. Delmarva_Struct

    Foundation Analysis and Design Software Recommendations

    I am trying to design foundations for a building addition for an exiting building. The columns that are near the existing building experience high seismic loads as they form a part of the SFRS of the new building structure. The footings for these columns will have highly eccentric (in both...
  6. Delmarva_Struct

    Tension only bracing for R=3 steel structure, SDC C?

    I am designing an R=3 steel structure with the SDC = C. I would like to install tension-only x-bracing to resist the seismic and wind loads. Per the process listed in AISC 341, for an R-3 SFRS, the brace is primarily checked for compression buckling as well as tension yielding. What is the...
  7. Delmarva_Struct

    Precast Concrete Shear Wall Foundations

    I am designing the foundations for a large precast concrete structures that is Seismic Design Category D. I have received the lateral loads from the precast designers from a separate analysis of the superstructure considering fixed based approach. The lateral loads are large and in designing the...
  8. Delmarva_Struct

    Precast Cocnrete double T roof in Arkansas with SDC C. Does it require a concrete topping

    I'm designing a Precast Concrete double T roof in Arkansas with SDC C. Does it require a concrete topping? as far I understand only SDC D and onwards need one.
  9. Delmarva_Struct

    Lateral/Horizontal Loads on Foundations. Book recommendations with worked examples

    Can someone could please recommend a foundation engineering book or any other text that details horizontal loads on shallow and deep foundations and includes worked examples? I know how to calculate the wind and seismic loads and apply them to the footings. I don't know the mechanics of the...