Building an industrial RO to operate up to 80bar pressure with duplex 2205 s.s pipe. The RO pressure vessels have groove coupling port connectors. I understand no fabricators can roll groove sch40 duplex pipe with std hydraulic roll groove machines as the duplex 2205 is too hard. Cutting the...