There is a requirement to install a Control valve in Boiler Feed Water Service with a Operating Pressure of 4100 Kpa and temperature of 130 Deg C. The requirement is to have a Plug material with 316SS with COCr but the available valve has Plug material with 416SS. Similarly the Seat Material is...
We are looking for Pump body for Sour water service having 60ppm Cl ( Chloride) and Design Temperature of 150 Deg C. Pump vendor has offered SS316L but due to high Chloride and high temperature use of SS316L is not a preferred option. Another option the Pump Vendor is offering is SS316L body...
Hi,
I am doing RBI on Boiler Steam Drum. Consequence category states Burst as one of the consequences. Our RBI system does not calculate the Burst calculation and does not give any output. I am planning to run Burst Calculation and need some help in calculation. Is there any literature where I...