Hello everyone!!!
The minimum length of engagements in threaded joints can be taken as 1*Dia. of thread. Then, how does the fluid power port connections like ISO 6149 have threaded connections that are less than 1D? What is the rationale behind the engagement length provided in fluid power port...
Hello all,
Recently, my organization is trying to make a animation video of our products to be in our website.
The guy who does animations is asking for 3D model with a high poly count(4 faces). He says that the model I've provided is only triangulated(3 faces).
Is there any way to change my...
Hello all,
I read that in pressure relief valves(hydraulics), there is knob, which can be adjusted to increase the spring tension, which in turn increases the relief pressure(pressure which pushes the spring and opens a path to tank).
This spring tension depends upon the spring constant, which...
Hey,
I am in the process of designing a shear loaded bolted joint. I came across a formula in Machinery's Handbook for thread length of Engagement as shown in pic.
The formula doesn't seem to contain any consideration for the load applied. So, does that mean the length of thread engagement...
Hello,
I have few questions regarding hydraulic clamping units(used in Injection molding machines to hold die):
1. What is the difference between clamp stroke(or forward stroke) & safe stroke in a clamping unit?