I use the following settings to save animation from ODB results. However, the image size often changes. For example, the size was 4096*2252 in my last saving, but it goes 4096*2273 this time. It seems that the size setting is randomly changing. And the terrible thing is that I can not change it...
Which one is the default setting? All I can find in the ABAQUS document is that "For ABAQUS/Explicit the default value for the tangent fraction is 1.0". But I just want to know if the default setting is "DAMPING COEFFICIENT" or "CRITICAL DAMPING FRACTION" and their default value.
I am using ABAQUS/Explicit to simulate the process of twisting and unloading a elastic strip. In my project, the twist moment must be high enough to make the strip almost buckled. However, in the unloading process, the mesh suddenly deteriorates at a certain moment. It seems like a common...
In my project, the material shows high plasticity, about which I know little. After reading some related papers, I find that the key is to simulate the cyclic uniaxial tensile test data from experiments. I used the Combined Hardening and Cyclic Hardening in...
I need to bend and twist a sheet into a spiral, but it is difficult to make it by setting moment at one side of the sheet with the other fixed. Maybe there is a more effective way to do this?