  1. martense

    assesment on large transformator

    Dear All, does anyone know where can i get assesment for large transformator 500 MVA, 500KV to 22 KV? thank you
  2. martense

    assesment for large generator and trasnformator

    Dear All, does anyone know where i can get service for assesment generator up to 200MW and and transformator up to 500MVA ?
  3. martense

    to test breakdown voltage of single daglass enamelled copper strip

    Dear All, i would like to ask how to know the breakdown voltage value of enamelled single daglass covered copper strip?can i use baker hipot test for this? thank you, regards, Marten
  4. martense

    to calculate the weight copper

    Dear All, if i have data for a motor : number of coil ,turn/coil,pitch,AGD,CMA,stator core length,core diameter, connection,slots, wire size, is it possible for me to calculate the weight of copper for the wire from those data?by the way this is for low voltage motor thank you, regards, Marten
  5. martense

    test for after high heat motor

    hi everyone, i have a motor 3 kv 125 kw, the motor was place in a room and the room accidently was on fire. after the fire, we have checked for the winding insullation resistance and the result was 2500 MegOhm, my question is what next step do i must do next to ensure the motor is still ok to...
  6. martense

    winding insullation resistance

    hi every one, i need help on my transformer, we have measured the value winding insullation resistance of secondary-ground of our transformator and the value was 0.1 MegOhm, the transformator is 1600 KVA, primer 20 KV to secunder 400 Volt, my question is , is it possible to have 0.1 MegOhm...
  7. martense

    unstable ampere in motor 3300 V 1250 HP

    Hi Guys, i have a trouble with my motor with name plate bellow : Voltage : 3300 V RPM : 3000 Ampere : 180 Ampere HP : 1250 HP the problem is when i each time i start the motor the ampere is not stabel for about 15 second around 17-24-40 ampere and after that...
  8. martense

    onsite generator assesment

    Hi everybody, does anyone know the standart procedure for onsite generator assesment? does surge, hipot ,winding resistance is enough? thank you
  9. martense

    magnetizing current

    Hi, does anyone know what is magnetizing current for tranformator? how to measure magnetizing current? and what is it for if i know magnetizing current value? thank you