Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: RWW0002
  • Content: Threads
  • Order by date
  1. RWW0002

    OCBF INVERTED V CHEVRON unbalanced force

    Forgive me in advance if there is an existing thread that discusses this topic. My search prowess seems a bit lackluster with the website overhaul. I am looking at an Ordinary Concentrically Braced Frame (OCBF) per AISC 341-10. Inverted V-Type chevron brace. Relevant code sections include...
  2. RWW0002

    Prefab Wood Truss Uplift

    Since we have several members active recently from the prefab wood truss industry I wanted to take a second to ask a question concerning the typical truss output. For background - When specifying dead load to be used to resist wind uplift, I generally specify 0.6x an approximate of "actual"...
  3. RWW0002

    ASCE 7-10 Drift on Adjacent Structures

    I am looking through the ASCE 7-10 requirements for leeward snow drift on adjacent (lower) structures (horizontal separation s less than 20'), and it appears there is a significant difference in the approach from ASCE7-05 to 7-10. To summarize, per 7-05 drifts were applied to all adjacent...
  4. RWW0002

    Diamond Plate Diaphragm

    Has anyone ever come across any information on the use of steel raised-pattern floor plates as diaphragms? I am considering using 1/4" floor plate welded to mezzanine framing as a diaphragm for mezzanine seismic resistance. Thanks,
  5. RWW0002

    Metal Stud Bracing - Brick cavity wall

    For a brick/metal stud cavity wall (veneer brick - 1" airspace - 2" rigid insulation - (exterior sheathing?) - metal stud - interior gyp.) curtain wall style construction. Is it common practice anywhere to allow the architect to omit the exterior sheathing layer at the exterior face of stud...
  6. RWW0002

    H JOIST REINFORCEMENT

    Does anyone know if James Fisher (or another author) has any recommendations for reinforcing H-series joists with double rod bottom chords in any of his joist publications? I am looking for some practical detailing guidance similar to that contained in TD12 or several of his other publications...
  7. RWW0002

    Metal Building Company-Conventional Steel Project

    One of our clients has recently been wooed by a one-time metal building company that has expanded into the world of conventional steel. They are touting the advantages of superior material purchasing relationships and advanced fabrication lines as well as engineering fees incorporated into the...
  8. RWW0002

    Southern Pine design values and the IBC

    I know there have been several posts concerning the reduction in Southern Pine design values over the past year, but varying agencies and sources seem to be at odds on whether NDS Supplement 13 (with an effective date of June 1 2013) has already taken affect for all new IBC-based design or...
  9. RWW0002

    Cb for Jib Crane Boom

    I am verifying the capacity of a jib crane boom arm (see attached sketch). The crane arm is free to swing 180° about the column, and the hoist load acts at the bottom flange of the boom arm. The design is fairly straightforward with some conservative assumptions concerning unbraced length and Cb...
  10. RWW0002

    Building Post supported on Slab-On-Grade

    There have been several posts in the past about slab supported post loads, but I am having a hard time finding code justification for supporting lightly loaded post loads on thin slab-on grade. I have a situation where I have many interior posts that the building owner would like to bear on a...
  11. RWW0002

    Direct Analysis Method AISC Example

    I am in the process of verifying the use of the Direct Analysis Method (per AISC Appendix 7)within a software package using the AISC 14th ed. examples posted on their website. (http://www.aisc.org/WorkArea/showcontent.aspx?id=29596) The example problem given for the DAM (Example C.1A) is a...
  12. RWW0002

    eccentrucally loaded bolt group in concrete

    Due to a some interesting existing conditions, I have been asked to attach a beam to an existing pilaster in a way that results in torsion on the connection. We will be drilling and epoxying anchors into the pilaster and they will be loaded with eccentricity in the plane of the connection. I...
  13. RWW0002

    cold-formed box beam lintel

    When calculating capacity for cold-formed steel box beam lintels(2- light gauge channels, toes facing inward, with track running along the top and bottom) I have been using the full lintel width for the unbraced length of the lintel (under gravity loading) and have calculated the capacity of the...
  14. RWW0002

    Slender Concrete Walls -

    I am in the process of re-writing some spreadsheets for changes to ACI318-08. While re-looking at slender walls, I have been using the PCA notes on ACI318 for worked examples to check by. When calculating Icr (ACI 318 Eq 14-7), PCA calculates "c" using the traditional nominal strength...

Part and Inventory Search