Search results for query: *

  1. Andiri812

    2 Speed 3ph motor rewind - assistance needed.

    And here I've been sitting with the reverse of your dilemma. I have a 3 phase 380V 2-speed Bench drill that I want to run on 220V single phase. Have been reading about all sorts of cowboy hacks with capacitors, static and rotary phase convertors but seemingly the only cost efecetive solution...
  2. Andiri812

    arcing noise coming from power transformer

    If the Trafo is small enough and has an OLTC then open it up and take a look... to heck with wasting time on the DGA unless you have a testing lab up the street. Otherwise if its new and under guarantee, get on the blower to the manufacturers and get them to address the issue.
  3. Andiri812

    Adjusting transformer tap changers

    The circulating currents between 2 or more paralleled trafos on different taps tend to cause additional heat build up over and above that of normal loading and effectively reduces the usable capacity of the trafo. We have a substation with 4 x 2,5MVA 30//6,6kV paralleled trafos of which 1 is 2...
  4. Andiri812

    HV Connectiors for Substations

    The smaller palm also has 3 times the thickness of the larger palm... 45mm vs 15. This would also have an effect on the amount of warping that would occur away from the bolting areas especially if using alluminium. Jointing compound is a must and definitley correct torque values and correct...
  5. Andiri812

    Transformer Cable + Surge Arrestor Connection

    That is how we were taught too although I had a different opnion especially with most of our pole mounted distribution trafos had the surge arrestor mounts below the main bushings. Droppers go to the arrestors first then only to the bushings. On querying this with one of our company engineers...
  6. Andiri812

    Can I build my own armature growler?

    I repair domestic appliances & power tools as a side line (excuse for a hobby). The power tools are sometimes an issue with suspected armature faults and the lack of a growler to test for shorts etc. Has anyone built their own growler or is it a project not worth the effort? Should I rather try...
  7. Andiri812

    3phase 3speed AC motor winding connections

    Thanks Scotty, I'll search the Dahlander connection, haven't heard of it before but never too old to learn something new. We have considered the VSD option on a new motor in terms of cost vs effort vs downtime on fixing the old. This unit has been rewound by our local motor rewind shop somewhere...
  8. Andiri812

    Reuse a step up Delta-Wye XFMR for a step down Wye-Delta application?

    @majesus, sorry to branch off on your topic. That's Canada... fair enough. I was wondering as we have a substation in Southern Africa where the zig-zags were connected as you depict with interlocking to the main transformer LV busbar CB then the wiseguys with thick glasses came and insisted the...
  9. Andiri812

    3phase 3speed AC motor winding connections

    Greetings all I have a 380VAC 3phase, 3 speed motor electric motor with 9 leads emminating from the stator. Power rating +/- 1Hp, 2,4 & 8 poles listed on the nameplate with speeds of 2800, 1400 & 700rpm respectively. The motor has burnt and now there is much speculation in the shop as to how...
  10. Andiri812

    Reuse a step up Delta-Wye XFMR for a step down Wye-Delta application?

    Curious... Shouldn't the zig-zag on the 600V (Delta) side be connected directly to the main transformer without CB's and not from the bus as a "feeder"?