Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations MintJulep on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: nabhan81
  • Order by date
  1. nabhan81

    crack in PSV spring

    Thank you all for your comments, Mr. Failure, you are the most guy who could understand me.. anyway I showed it to a corrosion specialist and he commented it looks like hydrogen crack
  2. nabhan81

    crack in PSV spring

    it's easy to say send to metallurgical lab, but what kind of test and what is the target of testing? what are the suspected mechanism? I am waiting for experts !
  3. nabhan81

    crack in PSV spring

    Spring is always live There is no much salts in the treated water Conductivity is 6400 micro simens/cm Chloride < 2000 ppm There is no indication of bending or permanent deformation Oxygen < 10 ppb I dont think 17-7 PH is not suitable for this service What kind of metallurgical testing will...
  4. nabhan81

    crack in PSV spring

    Hi, we are suffering from PSV spring crack Material: 17-7 PH stainless steel operating temperature: 221 F set pressure: 1760 psig size: 2" service: boiler feed water, good quality and well treated There is some corrosion in the spring but it is not on the carbon steel piping! See attached...