Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. strawhats2000

    Irregular Combined Footings

    Hi, I have seen that footing in a structural plan. When I came across such I usually combined the footing to create a bigger square or rectangle footing which is much easier to detail. However this engineer combined it in a L-shaped footing. I will like to know whether building codes allow...
  2. strawhats2000

    Changing Rebars or Delete Bar size in Etabs Beam Detailing

    Hi, Here is the output for the beam in etabs I have number of problem with this detaliing. First is that here we do not have barsize 14 and I have go to Define>Section Properties>Defin Baesize which list all the bars but no option is given to delete a particular bar size. Also I want the...
  3. strawhats2000

    Sunken Slab Detailing

    Thanks for your input. Where can I find such structural details?
  4. strawhats2000

    135 degree hooks in links (Detail) - BS8666-2005

    Hi, I need some lights regarding part of the table in BS8666-2005 explaining length of bends or anchorage in bars. I am using this instruction to create a 135 degree hook which has better anchorage than a 90 degree hook. On the 3 other corners, I have already draw the links as per...
  5. strawhats2000

    Strip Footing

    Hi Jayrod12, Here is the 2 design compared: https://ibb.co/g7NG2PC
  6. strawhats2000

    Strip Footing

    No in typical detail, the main bars are made up of R6 mild steel and the main bars are made of T10 main bars. In Chudley's book, it is just the contrary, the longitudinal bars are actually the distribution bars whereas the shortest bars along the width of the strip footing are the main bars.
  7. strawhats2000

    Strip Footing

    Hi, This is typical strip footing drawing used here. In Chudley's Contruction Technology, it is the reverse which is true and I believe he is right as B1 bars should span along the shortest distance. Actual Typical Drawings per Structural Engineers and Actual Practice Roy Chudley's...
  8. strawhats2000

    Sunken Slab Detailing

    Hi Tommy385, I have updated the detail as follows: Also there was an error on the length of the top bars which should be effective span/3. https://files.engineering.com/getfile.aspx?folder=e1e4bb75-edbf-4d01-bf8c-c1d5f9b2d09a&file=RND_000-001c_Forum_Proposition.jpg
  9. strawhats2000

    Sunken Slab Detailing

    Thanks KootK, Here is a reworking of your detail with a 100 mm. drop next to a beam. Is this ok? Please feel free to correct. In my case, the slabs are simply supported as beam and slab are not cast in one operation but separately. Also would you please give me some books or code references...
  10. strawhats2000

    Positioning RC Column

    Hi MIStructE_IRE, I know that 150 mm x 150 mm is out of norm with official code we are supposed to follow but most houses here is made of this size of column and sometimes we do have span exceeding 4.5 m and even G+2 house on such skinny support. This is a basic issue and I don't think we need...
  11. strawhats2000

    Sunken Slab Detailing

    Hi, I am asking for first floor or any other suspended floors that are supported on RC Beams and not Slab-on-Grade or oversite type of slab. Thanks for the email note.
  12. strawhats2000

    Positioning RC Column

    Hi. Here is a sample foundation and architectural layouts. I believe there are more columns than needed. However those are skinny 150x150 columns reinforced with 4T12 (+R6 links at 125mm). Please advise where I can remove columns. I believe a problem that may arise with a grid positioning...
  13. strawhats2000

    Sunken Slab Detailing

    Hi, This is a personal research for use in issuing plans to my clients (regular residential home plans). Thanks.
  14. strawhats2000

    Sunken Slab Detailing

    Hi, I am looking for any advice re. detailing of sunken slab i.e here a terrace that is 100mm. lower than the remaining slab at First Floor Level. Any documentations or examples of Two way or One Way Solid RC Slab Detailing with sunken slab, holes or pitch roof design in CAD or PDF format...
  15. strawhats2000

    Positioning RC Column

    Hi, A question of positioning Columns. Should it be at all wall intersection or should it follow a more rigorous grid line pattern with more or less same X and Y spacing between them? Thanks.
  16. strawhats2000

    Span/Effective Depth Ratio applied to 2 way solid slab

    Hi all, I am looking for information regarding span/effective depth ratio for 2 way solid slab. I have a garage with 2 nos. slab panels each 6m x 4m (Area of Garage 6mx8m). I want to know the followng: 1. Should be slab be designed as a continuous slab for support condition hence having a...
  17. strawhats2000

    Min. External Wall Thickness and Wall Ties Specification for Celluar Blockwall for Residential House

    Hi, Blocks regularly used here is Concrete Cellular Block of dimensions 450 wide x 200 high x depth of 100, 150 or 200 mm with 2 wall thickness namely 25 mm and 32 mm. The 450x200x150 with wall thickness of 25 have a maximum weight of 17.5 kg and is the most widely used in Residential Building...
  18. strawhats2000

    Min. External Wall Thickness and Wall Ties Specification for Celluar Blockwall for Residential House

    Hi. I am looking for Standards and Guidelines on External Wall Thickness and Wall Ties Specification of Cellular Blocks for Residential Building. Thanks. Nicolas.
  19. strawhats2000

    PROKON to analyse wind load on Aluminium Windows

    HI I am looking for notes on how to use PROKON to analyse wind load on Aluminium Window. Also looking for a steps by steps tutorials on PROKON. Many available in non-english format on youtube.com Thanks. Nicolas
  20. strawhats2000

    Column Link Design

    Hi all, I have 3 questions regarding Column Link/Binder/Lateral Ties design (Here applicable code is BS8110). 1. What is the basis for selecting a single restraining link or an enclosed link for intermediate bars in a column when clear distance between those bars are > 150 mm? 2. Given...

Part and Inventory Search