Mr. Gerhardt,
I appreciate your reply and eill do my best to reply to your comments. I offer:
1. The subject valve end use is a Vacuum Breaker valve off of a steam condenser, provided for and spec'd out by the Turbine Generator Supplier. It is designed for operation in a full vacuum service...
Currently purchasing a replacement 10" angle motor operated globe valve (see attached file) with the following parameters:
- End use is a Vacuum Breaker valve off of a steam condenser.
- Designed for operation in a full vacuum service (below the disc). The design pressure is 29.5 in. HG. VAC...