  1. aliccan

    Generator Belt Shrinkage and Burn

    I wonder if there is any calculation for the shock loads while selecting the pulleys ? This system is mounted on a vehicle with many many space restrictions. the maximum pulley diameter we could use was 4 inch (100 mm) one. Are there any document that i can use regarding the shock loads or is it...
  2. aliccan

    Diesel Generator Over Heat Problem

    Thanks all obviously it was a design error coming from the Air Condition Company, compressors were seizing the systems and when the a/c system turned back to normal the coollant temperature level decreased 6-7 C and didnt elevated after regime temperature level. Thanks all for the comments.
  3. aliccan

    Diesel Generator Over Heat Problem

    According to the oven tests and field tests none of the systems were over heating , now 4 systems are overheating and 1 system is working according to the tests. The mix is %50 and we have fully charged the oil according to the catalog data and oil sump stick. I am suspicious that at 50...
  4. aliccan

    Diesel Generator Over Heat Problem

    We are currently testing five diesel generators at the field . all of the systems are identical (As we know) The systems are operating Air Condition Compressor @ 21 Bar 310 cc and 24V 300 Amp alternators Air condition compressor catalog power is 8 kW Alternator is consuming 1 kW due to low...
  5. aliccan

    Belt Burn and Shrinkage Overtension

    My question is if i buy a 8PK random tensioner from the market and adapt it to my system will i have the necessary tension ? The Air Condition Compressor is 8 PK and when i calculated the power and take a service a factor of 3 i was still at safe regions so that i designed the complete system...
  6. aliccan

    Belt Burn and Shrinkage Overtension

    Why the result shall be grief , i didnt get that ? Thanks for your comments. http://files.engineering.com/getfile.aspx?folder=ce011e88-6afa-4d0a-923c-6a7dd4e049f3&file=Shrinked-Belt.jpg
  7. aliccan

    Belt Burn and Shrinkage Overtension

    Hi All ; I have designed generator driven belt and pulley system and used mercedes bus belt tensioner to tension 8 PK 1150 belt at 21 kW load. The tension is around normal levels as i measured by gates tension meter. The system has a flywheel shaft with 200 pulley on it and it is driving a 100...
  8. aliccan

    Generator Belt Shrinkage and Burn

    Hi All ; I have designed generator driven belt and pulley system and used mercedes bus belt tensioner to tension 8 PK 1150 belt at 21 kW load. The tension is around normal levels as i measured by gates tension meter. The system has a flywheel shaft with 200 pulley on it and it is driving a 100...