I wonder if there is any calculation for the shock loads while selecting the pulleys ? This system is mounted on a vehicle with many many space restrictions. the maximum pulley diameter we could use was 4 inch (100 mm) one. Are there any document that i can use regarding the shock loads or is it...
Thanks all obviously it was a design error coming from the Air Condition Company, compressors were seizing the systems and when the a/c system turned back to normal the coollant temperature level decreased 6-7 C and didnt elevated after regime temperature level. Thanks all for the comments.
According to the oven tests and field tests none of the systems were over heating , now 4 systems are overheating and 1 system is working according to the tests.
The mix is %50 and we have fully charged the oil according to the catalog data and oil sump stick.
I am suspicious that at 50...
We are currently testing five diesel generators at the field .
all of the systems are identical (As we know)
The systems are operating Air Condition Compressor @ 21 Bar 310 cc and 24V 300 Amp alternators
Air condition compressor catalog power is 8 kW
Alternator is consuming 1 kW due to low...
My question is if i buy a 8PK random tensioner from the market and adapt it to my system will i have the necessary tension ?
The Air Condition Compressor is 8 PK and when i calculated the power and take a service a factor of 3 i was still at safe regions so that i designed the complete system...
Why the result shall be grief , i didnt get that ?
Thanks for your comments.
http://files.engineering.com/getfile.aspx?folder=ce011e88-6afa-4d0a-923c-6a7dd4e049f3&file=Shrinked-Belt.jpg
Hi All ; I have designed generator driven belt and pulley system and used mercedes bus belt tensioner to tension 8 PK 1150 belt at 21 kW load.
The tension is around normal levels as i measured by gates tension meter.
The system has a flywheel shaft with 200 pulley on it and it is driving a 100...
Hi All ; I have designed generator driven belt and pulley system and used mercedes bus belt tensioner to tension 8 PK 1150 belt at 21 kW load.
The tension is around normal levels as i measured by gates tension meter.
The system has a flywheel shaft with 200 pulley on it and it is driving a 100...