  1. cfontes

    AWS D1.1 tensile test piece

    I asked because in the Brazil some welding inspector reproves the test and the joints if the weld presented length of reduction section less than 60 mm. The interpretation is reprove the sample and prepare a new joint, but I don’t found in the AWS D1.1 a note that I can use in this case when I...
  2. cfontes

    AWS D1.1 tensile test piece

    Thank you, The question is if I have a weld joint with weld metal around 20 mm plus 0.5" of HAZ and BM I do not have 60 mm of length of reduction section. What the interpretatio for this case?
  3. cfontes

    AWS D1.1 tensile test piece

    hello, I would like know what is the interpretation for tensile test piece with 60 mm min of length of reduction section if my weld metal present only 20 mm of widest face due my thickness is small (9 mm)? Thank's