susanbhj, MAWP for a vessel is measured at the top of the vessel (i.e. without hydro-static head); however, for each competent, MAWP shall be computed based on min. thickness and corroded diameter; Hydrostatic head at a point in a vessel must be added to the pressure used (normally vessel MAWP)...