There is IGV and which is in auto, but during low load requirement the BOV was normally observed as open 18% for both compressors even at that stage minimum current is reached, may be the reason for opening BOV
The trip happeneed at two different loading conditions during starting of loading...
''Trip is at 50.8 microns and registered 127 microns during each trip''
This is thereason we were suspected probe related issue and change two probes checked all wirings, now thi is shifted to other probe
Dear Mr.rotaryw
Thanks for your replies and quires, kindly find replies
Trip is at 50.8 microns and registered 127 microns during each trip, and which is the cause of trip, not coming during deceleration.
Compressor trip sequence may initiated once it reaches and functional check was...
Dear All
kindly guide with your technical excellence and experience.
Compressor Manufacturer CAMERON
Model No TA-3000
Driven by motor of 421 KW
integrally geared 3rd stage compressor
having capacity of 3442 nm3/hr. (Rated)
Motor rpm 3555
1st stage pinion rpm 8880
2nd stage pinion rpm 16720...
Dear All;
It's regarding the 3 number of Boiler feed water pump installed at site , all having API plan 23.
Following are the observation
As per API plan 23 the seal FO (Flush Out )should have more temperature and high point vent should be in this line
Flush in to seal from cooler should be...
Dear All;
Thanks for your valuable inputs.
Continuation to our discussion ;
API 614 forseen the even of total lube oil failure.
Both Main and auxilary pump failure and the run down tank and emergency oil pump come under that.
in this case if main oil pump fails to develop pressure and...
Thanks CaracasEC & rakuday
rakuday u tested ur machine at site... To verify the coast down implication.......
So u r suggesting it is ok...the design.
caracasEC. I am agreeing to u r stand....but when it is advanced to a stage
The equipment is installed and ready to start in months...
What...
Dear CaracasEC;
I gone throgh the API 614 1.4.7 you are correct; how we can explain reliability of shaft driven pump is less than that of electric driven any supporting documents or standards; since the manufacturer saying that the " The design is safe with to indipendently driven independently...
Thanks to one and all;
In case of us factory test already completed and the coast down test didn;t done or data is not available.
Wheteher mechanical test includes coast down test also as per API 617/614?
one more thing in commissioning stage, all depend on the contract between purchaser and...
Dear All;
Kindly guide me to decide what is the correct stand in the following issue?
For our new Chlor Alkali plant we are installed chlorine compressor of M/s Siemens make
940KW,10088 Rpm, 10048 nm3/hr flow 3 stage centrifugal compressor driven by electrical motor.
Oil system main oil...
Dear All;
Kindly guide me to decide what is the correct stand in the following issue?
For our new Chlor Alkali plant we are installed chlorine compressor of M/s Siemens make
940KW,10088 Rpm, 10048 nm3/hr flow 3 stage centrifugal compressor driven by electrical motor.
Oil system main oil pump...