Hi,
My background is Process Engineer.
I'm tasked to create concept/design of new oil custody transfer system for my company.
The one of the specification for the meter is as follows: Sensor range shall be 0 % - 5 % water in oil with an accuracy of 0.2 % absolute.
That is one of the...
Thank you for confirming Artisi, below is my pump requirement :
Nonhazardous transfer pump
fluid : water
discharge head : 220 ft
NPSHA : 24 ft
single stage, single volute, overhung pump
Rated power : 30 kW/40 HP
From several vendors that have send quotation, the RPM of the motor usually around...
Thank you for your kind response.
High-level description would be enough for now
I will ask again if I have more question regarding pump lubing system.
Hello,
I'm preparing a datasheet for quoting centrifugal pumps, and I have questions about the lubrication system.
Could anyone please explain on what application these lubrication system would fit :
1. Ring Oil
2. Oil Mist
3. Flooded
4. Flinger
5. Pressure lubrication
6. Grease
Thank you...