dgallup thanks for the advise I will take that into consideration. But I really need quantifiable data as this is a 1st piece sample that needs dimensional approval.
What is the best way to measure/inspect a positional tolerance of a circular magnet? For instance... Position Tolerance .002 |A|B|.... Datum A is outer diameter (ø0.512), Datum B is flat surface.. Thickness of magnet is .130 and Thru hole at the center of the magnet is ø0.033 this is where the...