As per API 660 in pressure testing below point is mentioned please elaborate
10.2.11 Flanged joints that have been taken apart after the final pressure test shall be reassembled with new
gaskets and re-pressure tested. Self-energizing seals can be reused, subject to approval of the...
this is one of the case of the compressor
Actually the compressor is designed for other gas composition with high suction pressure and discharge pressure
but thank you will check the recycle valve duties that was not thought by me
hii Georgeverghese
my calculation are showing what you said
increase in power however my rod load are acceptable range and also my motor hp are higher i can try this case
A Recip compressor with below data
suc. press : 9.1 Barg and disch. press. : 41 barg ( 2 stage machine)
flow: 21700 nm3/Hr
now if suc press. is increased to 10.1 barg with no change in flow and discharge pressure
what wil happen in compressor output and other things?
may be a basic question...