  1. MIMAN

    Allowable Stress Values

    Thanks. I actually found 23.3 Ksi in ASME 2015. I have been trying to explain to some Chemical Engs. that Tmin is not simply obtained by subtracting the Corrosion allowance from the Nominal on the U1 form.
  2. MIMAN

    Allowable Stress Values

    Service Temp. is 400°
  3. MIMAN

    Allowable Stress Values

    Does anyone have access to the Allowable Stress Tables in ASME Sec. 2D? I am trying to locate the allowable stress for SB-168 N06600 in order to accurately calculate the Tmin. values for a pressure vessel.
  4. MIMAN

    API Inspections

    Does anyone have a Pro's and Con's list for why sites decide to contract their API inspection services out as opposed to hiring inspectors directly?
  5. MIMAN

    ASME Nameplate Replacement

    I need some direction on this. The site that I work at has "several" much older, second hand PV's that are missing their nameplates. Some of these vessels have the original U1's on file while others appear to be missing. I need to know who I can contact to have the nameplates replaced. I assume...
  6. MIMAN

    Strategic Planning for Fixed Equipment Replacement / Upgrade

    Does anyone have a good Excel or Powerpoint template for strategic planning of fixed equipment at an industrial site.
  7. MIMAN

    Grounding Wire Requirements

    What is the code requirement when running grounding wire from industrial equipment that is located outside. Does the ground wire need to be ran through PVC conduit or can it be ran as an exposed wire?
  8. MIMAN

    Can we delete old UT data??

    What does the code regulations say about removing old UT data from the calculation data set? I have a pressure vessel that is roughly 20 years old. The remaining life calculations indicated that one CML location (nozzle) needed replacement, so I had a coded contractor replace the nozzle. Am I...
  9. MIMAN

    Mechanical Integrity Manual

    As part of the MI manual that I am developing as part of our overall program, I would like to add a RAGAGEP matrix. Does anyone have an example of a RAGAGEP matrix that I could modify for my own use?