Hi. Reconfirmed with the manufacturer.
All hydraulic lines are definitely linked. And the offset of 1.5m forward is definitley the case.
Strange. Googling these types of trailers, i see a lot of photos (unconnected to prime movers) being similar and not tipping forward. And i suspect all...
Hi
Im trying to understand the statics of how this possibly works.
5 axle truck trailer 30m long overall on the show room floor. Self weight of trailer is 25 tonnes.
All 5 axle rows (1.8m apart) are hydraulically linked so the centre of reaction is theoretically under the third axle. Trailer...
Appreciate the responses to you both. Thanks.
If its any help...the office space has egg crate grilles in ceiling tiles and i assume thats for the return air ... so maybe not 100 percent fresh air unit??
To be honest, being a novice at this.. i did not know 100 percent fresh air was even...
Hi all
I am a not a hvac engineer, but would appreciate some help in understanding something
This is in regard to a typical Brisbane 20 storey building with AHU on every floor (each floor has a small mech plant zone and the AHU is inside that room)
My question: Are the AHU cooling coils meant...
Ah yes. I see what u mean. And yes there is a designated separate ahu plant room to one side of the plan. It appeqrs as though this office has the plenum in the ceiling.
Thankyou that really helps.
** out of curiosity...would there 'eventually' be a short run of ducting from the ceiling...
Hi all.
I am reviewing some office AC ducting drawings and had a query regarding the return grille that are typically shown in plan.
The office is a mulitstory building with drop-in ceiling tiles.
On the plans, i see all the supply air ducts and the direction of airflow feom the AHU. But...
Thanks for the responses so far. It is an unusual one.
But why a mesh filter? I would have thought it was too coarse! And l let fibres and other sperical dust thru.
It is an interesting observation of the fibres accumulating on the entering face. I would think...given the size, most could...
Hi.
Hoping for a bit of advice regarding dust sizing for filter selection. It seems as though most specs and literature think of dust as roughly spherical in shape.
But In regard to fibrous dust (eg wool batts etc or husk factories) the fibres can be 0.1 micron diameter but the length can be 5...
[img https://res.cloudinary.com/engineering-com/image/upload/v1667631708/tips/PNG_image_ujra7k
Hi. I have an issue with a single storey timber framed brick veneer home. No structural issues anywhere. However, There is a random horizontal hairline crack mid height of 1 wall..unexplainable!
The...
HI ALL
Just a topic of conversation in the office recently, but is anyone able to shed light on what filter standards were applicable for fine filters througout 1980s in Australia?? We dont think a Mserv rating code was used as we think ASHRAE developed it just befor 1990. Any advice...
hi.
i have a situation where i need to determine the pressure under a square footprint load applied at the surface of the soil.
I am interested in the vertical pressure at roughly 1 to 1.5m beneath the square pad. (using boussinesq soil theory).
The square pad is susecptible to vertical load...
hi and thanks to all that contributed. Particularly ProgrammingPE.. your first paragraph explained it really well - so thank you.
To reiterate, I think the mention of the slip is the key!!
Upon jack release, if there is no slip(unrealistic case)...ALL the load is transferred at the discrete...
Hi All.
In regard to a simply supported pretensioned beam (with straight horizontal and fully bonded strands for the purposes of this discussion)...this does appear to be a fundamental question, but is in fact a little more complex…with an understanding of strand strain and concrete strain at...
Hi.
For the AS100 steel code, it requires that the ends of compression elements be restrained inplane and restrained out of plane....which is understandable. Normally, the ends of the column are checked to see if there is a load path to resist 2.5% of N* in the out of plane or inplane...
Hi all. Its not coal ash. In any case its only in traces. Also, the bore log makes no memtion if its organic. Not sure how they'd be able to tell if it was inorganic anyway. It is a bush land greenfield site with no prior useage history. So i am leaning to a past (ie very long time ago...
Hi guys. Thanks for the response. Appreciate it.
Fattdad: When you say the "not a good log because the nature of the stratum is not considered", are you meaning that it's because the geotech engineer should have stated if it was fill or not (or given some more info?? All it says at 2m down is...
Hi .
My apologies for the seemingly silly query, but I have a borelog that identifies traces of "Ash" at around 2 meters depth. The log does not state the strata is fill.
In terms of understanding the term..."Ash", is this meant to be a soil geological term , OR, is it literally meaning ash...
CMCCJRS you have been a great help. thank you for helping.
Its a good point you mentioned regarding the filters for the AHU unit from the eighties. i suspect since that time, the filters would heve been replaced dozens of times and at the very least, i suppose a modern day G4 inserted (although...
hi CMCCJRS
That was an excellent explaination to a novice like myself. Thank you for being patient and explaining so well.
If i could ask one final question in regard to your comment about some AHUs possibly only having one filter...
If that were the case (ie one filter only), would they be...