Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. u0406346

    Seal leaks prematurely at High Pressure but holds at Low pressure

    What is the seal face config? concave or convex or dead flat?
  2. u0406346

    Advice on plan 53A installation

    Sorry for the incorrect statement, the seal pot should not be located directly above the mixer or seal, but should be located as close to the mixer as possible while leaving sufficient room for operation and maintenance. 35mm diameter seal should not be producing much seal heat, estimate...
  3. u0406346

    Advice on plan 53A installation

    JJPellin is correct, thermo-syphon is the main reason why the height requirement for the seal pot. Note that your seal pot should be directly above the seal also, cannot be too far away radially, eg. 1 m away. The concern here is because, circulation of the barrier fuid in the closed-loop system...
  4. u0406346

    Seal Plan 53A and 53B

    Hi Kanif77, for Plan 53A, the seal pot is needed to be consistently pressurized by Nitrogen. If the nitrogen pressure drops, the sealing system would be converted into Plan 52, of which the process fluid will flow into the sealing system and inboard seal faces now become lubricated by the...