@Mortena,
Yes, the orifice plate bore size calculation is the main task. But with the size cavitation analysis, noise calculation and plate thickness needed to check also. I was asking for the checklist.
Sukanta Mondal.
Dear MortenA, did you calculate only the orifice area/size?
Is there any noise calculation procedure for the restriction orifice plates for liquid services?
Sukanta Mondal.
Thank you very much to all. I concluded to check the noise level, cavitation and plate thickness for the RO. This post is also enough helpful http://www.eng-tips.com/viewthread.cfm?qid=305795 where the practical experience was shared nicely with remedy.
Sukanta Mondal.
Hi All,
What are the standards for sizing of restriction orifices? Needed for liquid and gas-liquid flow. Does AGA 3, ISO 5167-2, ASME MFC 3M really highlight this issue? I went through them but not satisfactory and specific.
The calculation can be done but the thing is the CONSIDERATIONS. For...