Dear Friends,
Pl. find attached figure which needs to be radiography testing as per client specification and this joint considered as a GOLDEN joints. If it is in simple butt weld(pipe to pipe/elbow) then no issue. we can can take RT and simple skip Re-hydro.
But the joint configuration is...
Yes, it is new construction. But as per our standard says that joint shall be considered as a golden joints and go for RT and MT or PT.
RT is not feasible for that joints. Then what is your suggession.
Dear Friends,
We are facing one problem regarding 2" dia Piping weldolet Branch connection.
The main header line was 8" dia. which has already Hydrotested.
Now, there are some modification came and needs to be installed 2" dia weldolet on 8" dia header line.
My question,is as per ASME B 31.3...