Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Jerehmy

    Slide Rule Era

    Just wanted to say I’ve found SREs website useful in the past and hope a new incarnation comes about!
  2. Jerehmy

    Miami Beach, Champlain Towers South apartment building collapse, Part 02

    I just have a few thoughts: 1. Its very unlikely the penthouse, even if unaccounted for (which isn’t likely, as a recent interview indicated it was accounted for), to cause a failure. I agree with XR250 that the majority of the floors were likely no where near their design loads. 2. The...
  3. Jerehmy

    Hard Rock Hotel under construction in New Orleans collapses...

    If you watch the beginning over and over, it looks like the top two slabs deflect a column line or two in from the edge. The edge of the top slab rotates and is pulled back. Looks like those slabs failed in flexure first. That one crane in the background tilts forward as if it was resting load...
  4. Jerehmy

    2/2 V Grip Deck

    SDI came through and sent me the Bowman catalog from 1985. I've attached it in case any future person who comes across this thread needs the same information. Also, based on a site visit, it looks like the contractor installed the 1-1/2" not the 212. Go...
  5. Jerehmy

    2/2 V Grip Deck

    https://d-macindustries.com/ask-d-mac/my-drawings-show-type-ir-deck-what-is-that/ So apparently theres 212 V-grip and 312 V-grip. I found it listed in some UL assemblies: http://isolatek.com/ul-design-thickness/2019/Dry%20Mix/D859.pdf http://www.metaldek.com/downloads/ul/P920.pdf It may have...
  6. Jerehmy

    2/2 V Grip Deck

    I'm not sure. The catalog in the link is from 1973 and has a "Type V" composite deck. That's all I could find. It's not a big deal as I can conservatively calculate the capacity, but it would have been great to be able to identify the deck. Thanks for you help.
  7. Jerehmy

    2/2 V Grip Deck

    It says 4-1/2” concrete slab above the deck callout and section A-A shows as 4-1/2”. Any other ideas 😬.
  8. Jerehmy

    2/2 V Grip Deck

    See the attached pdf. The concrete slab rests on a "2/2 V Grip Deck". V grip deck seems to be Inryco (https://www.eng-tips.com/viewthread.cfm?qid=361447), but I have no idea what the "2/2" means. Anyone have any idea about this nomenclature...
  9. Jerehmy

    corrosion resistance for "regular" Tapcon screws

    Tapcons are coated in Climaseal which is a thermoset polyester. Just regular steel underneath. It is recommended to use hot-dip galvanized, stainless, copper, or bronze with pressure treated fasteners. I personally have no experience with tapcons in conjunction with PT wood. But i’d have to...
  10. Jerehmy

    Generic wood I joists

    I love it. First I'd find out how old the building is. Then I'd measure exact flange sizes, this should give you a good idea of when it was manufactured too. Then I'd call local distributors to see what manufacturer they may have stocked around that time. Kind of weird there's no stamp though...
  11. Jerehmy

    Agricultural Buildings Exempt from Code Requirements

    In Pennsylvania, agriculture buildings are exempt from the Uniform Construction Code. Pennsylvania has a state-wide building code, local codes only cover zoning. Farmers also really put up a stink about permitting too and claim "farmer's rights". They pretty much do whatever they want and the...
  12. Jerehmy

    Distortional buckling of C channels without lips

    The flange does buckle. You use a reduced, or effective, flange width based upon whether the flange is stiffened at both ends (by the web and a lip) or just on one end (by the web). In the first case, your effective flange width is much greater since it is stiffened at both ends. But, you must...
  13. Jerehmy

    Distortional buckling of C channels without lips

    Rb, I'm going to have to disagree with you interpretation. The first sentence of specification section C3.1.4 clearly states "The provisions of this section shall apply to I-, Z-, C_, and other open cross-section members that employ compression flanges with edge stiffeners, with exception of...
  14. Jerehmy

    Distortional buckling of C channels without lips

    Mike, lips are the little ~ 3/4" long pieces that are parallel to the web but on the opposite side of the flange. Tramyer - The commentary for C3.1.4 in 2007 states "Distortional buckling is an instability that may occur in members with edge stiffened flanges..." Therefore, it is not something...
  15. Jerehmy

    Allowable Tensile Capacity of wood sheathing values

    Your diagram induces shear not tension. Thats a different situation than the uplift scenario in the sdpws. Unless we’re missing some other bit of info.
  16. Jerehmy

    Concrete Discoloration (Blue-Grey)

    Friend of coworkers slab is discolored below grade and was curioud as to why. Is this discoloration caused by slag in the mix...
  17. Jerehmy

    Superior Wall Builder's Guideline Booklet 2006

    There are many parties involved which has convoluted everything. As with most errors, lack of communication seems to be a primary factor. Homeowner acting as GC, excavator hired the precast company who then subbed the installation out to another company. The township approved and stamped...
  18. Jerehmy

    Superior Wall Builder's Guideline Booklet 2006

    A 2-story wood framed building sits on a precast foundation. Foundation is 28x54. The house is 28x38 (8’ short on each side). So the first floor diaphragm has to tranfer the shear to the end walls in combination with the bond beam likely helping distribute. There’s no interior foundation walls...
  19. Jerehmy

    Superior Wall Builder's Guideline Booklet 2006

    Does anyone know where I can find the booklet guide from 2006? Only 2010 and 2018 show up on google. It's for litigation purposes so the booklet used at the time it was built is important. The only reason I know 2006 exists is it's reference in ESR 1553. Thanks
  20. Jerehmy

    Wood Diaphragm Chord Discontinuity - Transfer Diaphragm

    Malone has a workshop slide show and a publication regarding wood diaphragm discontinuities links to which are posted below. I unfortunately don't have his book. http://www.woodworks.org/wp-content/uploads/2015-Workshop-Advanced-Diaphragm-Analysis.pdf...