I would like to reiterate:
The wellbore temperature is 180oC at the bottom, the water pumped is at 10oC and we want to cool the tool to 70oC. Heat transfer will be between water and coil tubing (convection) then from the coil to the water on the annulus (outside) of the coil (also convection)...
[highlight #729FCF][/highlight]