We are able to check capsule moisture levels throughout the process. At specific times with moisture analyzing equipment of which we are able to base our drying times on.
Compositepro,
The 500mg shell is holding water content. We only need ro remove 10% of the water content from the shell. Just the content of the shell.
Do i need to calculate in the other fill material inside the shell, the 2800mg - 500mg = 2300mg. I dont believe i need to calculate in the other...
The total mass per capsule is about 2800mg.
But we are only removing water content from the shell of the capsule. The shell weighs about 500mg. Of which we need to remove 10% of that moisture content from the shell.
Our goal is to be at 68F dry bulb and 20RH.
That is achievable with a liquid dessicant system, but the product load really determines what size system to use. So we are really trying to be as accurate as possible with the product load and moisture of lbs/hr removal. We do not want to make a...
We are removing 10% of water content in product, not 10% of overall product weight.
So you believe it should be (quantity removed per product, per product meaning 129lbs of product each hour / 36 hours X existing product load)?
Now would my existing product load be basically the 129lbs hour...
Looking for some help in regards to "product moisture load" in LBS/HR of moisture removal to size dehumidification equipment properly. We have pharmacuetical softgel capsules of 500mg each, of which we need to remove about 10% moisture from this product. This issue is that this 10 % water...