ETAP is limited to Stainless Steel, S304 grounding rod and our client is requiring Stainless Steel, S316L for grounding rod.
I have tried to add stainless steel S316L using GRDLib.mdb using microsoft Access but it is not working.
Is there any method to show and add Stainless steel S316L in...
In the attached file, line and bypass contactor are provided. One operation engineer from the client side commented to remove the line contactor. Is it ok to remove the line contactor, if it is not remove thus it give additional protection. I want to know also what is the purpose of the line...
The client has asked me to provide the total power input in kW of a Package AC.
The electrical data for the Package AC are: MCA = 63.8 Amps ; MOCP = 90 Amps
Compressor RLA (2 ea) = 22.4 Amps & LRA = 150 ; Fan Motor = 1.7 Amps.
Note: Voltage is 460-3ph-60Hz.
Based on the above data, How can i...
The fluid is industrial waste water, TDH = 30 m, Duty = 885 m3/hr, Sunction = Flooded, Fluid temp = 60deg C, Sump depth = 3m , Motor Voltage 460V, 3ph, 60HX, Exd, IE3 efficiency.
The vendor calculated at fluid temp at 40degC, the selected motor rating is 112kW (150hp).However, when he changed...
Can someone explain the effect of fluid temperature to the motor size.
Mostly, Vendor provided to size of motor at 40 deg C to be 112kW (150hp).
However, as per our client the fluid temperature shall be used is 60 deg C. Again, the pump vendor have size the motor to 160kW (200hp).
My question...
Is it mentioned in any standard to provide Ground Bus for Electrical in a Electrical room.
Can someone provide me standard reference regarding ground bus bar for electrical.
In any electrical code, is their a limit that the setting of a ground fault protector to be maximum say t(s)= 1.0 and I(g)= 1.0 . Is their any calculation? The breaker rating is 150A.
see attached. Our inspection is asking a setting...
This question is for code book understanding. Article 220 is reasonably clear as to the definition of continuous and non-continuous loads and how they affect the size of feeders and services.
My question is,
"How does the NEC expect the designer/engineer to treat the loads that have been...
The main feeder 150AF/150AT is installed in a outdoor switchrack has a 150a ground fault detection feature (EATON ELJBN3150W). It is supplying a UPS (10kVA, 480V) inside a building from a 100AF/30AT circuit breaker. The ground fault unit setting at the switchrack is t(s) = "1.0" and the Ig (A)...
Our Client is adding 700hp 4.16kV Squirrel Cage Motor for Compressor. Then Vendor quote 400A Bus rating and Current Rating is 110 A. How is the Soft Starter rating is selected? Is their a chart or code define the sizing of the Soft Starter Controller. Please help
Additional Data:
Motor is S1...