Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. DaniMP

    Anode in filters

    Thank you everybody !!!
  2. DaniMP

    Anode in filters

    Hi everybody ! A quick question : My supplier of salted water filters has put the galvanic anodes in the top part of the filters. The entrance of the filters is by the side approximatively at 4/5 of the height of the filters, so the anodes won't be in the water, except during the washing (the...
  3. DaniMP

    Anode in filters

    Hi everybody ! A quick question : My supplier of salted water filters has put the galvanic anodes in the top part of the filters. The entrance of the filters is by the side approximatively at 4/5 of the height of the filters, so the anodes won't be in the water, except during the washing (the...
  4. DaniMP

    Baffle on a new tank

    Thank you dhengr !
  5. DaniMP

    API 620 tank design

    Hi ! Could I use this thread to ask a few questions (I did not find in API 620 / 650 hints or answers regarding these issues) : - in designing my storage tank, are there some guidelines regarding the diameter / height ratio to observe ? - do I need to leave some minimum space around the tank...
  6. DaniMP

    Baffle on a new tank

    Thanks ! Unfortunately, my level won't be constant in the tank.But of course I could design a weir box and when my operator want to remove the oil phase, he will artifically raise the level in the tank. So there would be no solution with a baffle if I reinforce it or else ? My constraint is...
  7. DaniMP

    Baffle on a new tank

    Thank you fegenbush ! I'm not sure I can have an oil skimmer as my oil is very paraffinic and I would fear to have the skimmer stucked on its pole if my heat control (heat coil) does not work well / it is too high for the coil... IFRs : what is a saw-tooth weir box ? Thank you !
  8. DaniMP

    Baffle on a new tank

    I have looked at API 620 / 650, and I don't tjink they ever talk about this kind of issues ? Thank you again !
  9. DaniMP

    Baffle on a new tank

    Hello everybody ! I am designing a new oily water tank, and I want to have a compartment with a baffle so that the oil at the surface can flow from the main compartment (the tank) to the oil compartment. Are there any norm / constraint that I need to know ? For example, I have uploaded some...
  10. DaniMP

    Piping classes

    Thank you, I looked up ASME B.16-5 and everything was there !
  11. DaniMP

    Piping classes

    Hello everybody ! A quick question as I cannot figure it out by myself... One of my piping classes is for water, it is a carbon steel 600 lbs rating with a CA of 1,27 mm. Material is as API 5L grade B. My Temp / pressure couples are as follows : Pressure (bar) : 102 102 92.7 Temp (°C) ...
  12. DaniMP

    velocity at pump inlet

    2,5m/s will be for rated flow, half for normal flowrate ! My pump is single stage, single suction, radially split volute type
  13. DaniMP

    velocity at pump inlet

    Centifugal pump and the flange is also 12" ! (why would it likely be larger ?)
  14. DaniMP

    velocity at pump inlet

    Thank you littleInch ! If the problem is only the pressure drops due to friction then I won't worry, I have only a few dozen meters between the tank and the pump... :)
  15. DaniMP

    velocity at pump inlet

    Actually I was not very accurate, the water is coming from a tank, and the LSLL is several meters high, so no problem with NPSH (and 80C is design temp, it will be around 40°C). But just to understand, what is the risk with the velocity ?
  16. DaniMP

    velocity at pump inlet

    Hello everybody ! A quick question regarding the velocity in the pump suction pipe : We have a water pump designed for 100 000 bbld. The water is @ atmospheric pressure and 20 - 80°C in the suction system. I would like to use a 12" pipe for suction, but the velocity would be of 2,5 m/s, and I...
  17. DaniMP

    Oil skimmer

    Thank you LittleInch. Actually that is what we have in our process. But we have some operating problems and that is why we want to have this skimming option in the storage tank. regards, Daniel
  18. DaniMP

    New nozzle on a steel storange tank

    I'm sorry... my copy of API 650 does'nt have a section 5.7.2.3 ???
  19. DaniMP

    Oil skimmer

    The tank won't be at a same level continuously (thanks fegenbush).
  20. DaniMP

    Oil skimmer

    Thank you IFRs for your answer ! Yes that would be one solution. But are there any alternative ? What are the best pratices of the industry for skimming an oil phase at the surface of an oily water tank ? Thank you !!

Part and Inventory Search