I don't have any oil cooler for this system.
I never thought of the cavitation problem until you brought this up. Thanks for the comment. I will check the system once i go to site again, which is next month. :)
As of now I will try to study the system through theory and PID
I have a hydraulic system with manifold and cartridge valves. Oil is leaking for the manifold. When inspect, found that some o ring is damage. The temperature of hydraulic oil is high enough, that cause the damage of the o ring.
High pressure in system will increase the temperature. I don't...
Sorry for the late reply. I live in SEA. Please refer to the sketch.
Yes. The volume of dampener is greater than 1 liter. Only gas is leaking at dampener. By right the time taken to reach operating pressure is more, but that is in the range of a few seconds.
No oil is added to the reservoir...
Refer to the photo.
Unloading valve set pressure = 130 bar
Pulsation damper pre-charge N2 pressure = 50 bar
Pulsation damper nominal liquid volume = 1 liter
Consider the following scenario. Pulsation damper gas valve is leaking gas. As liquid is incompressible, in order to reach 130 bar...
I came across an excel sheet, which can calculate the tube exit surface temperature in fire tube boiler.
E = exp (Surface area*U/Flue gas weight*Cp)
Where,
U = Overall heat transfer coefficient
Cp = Specific heat at constant pressure
Tube gas exit temperature = [(FEGT - Tsat)/E] + Tsat...
Dear All,
I am having trouble to finding the heat transfer coefficient of spiral retarders. The sketch of the tube is shown in the link.
[highlight #FCE94F]My objective is the find the heat transfer coefficient for the spiral retarders[/highlight]. With retarders, a turbulent flow will be...
Chicopee, what you mentioned about the efficiency is near to what I had calculated; 83%. So far I had done the excel sheet. I am stuck at here.
Actually part of the reason why I take up this challenge is to understand better the mechanisms behind the boiler. The process is more important than...
Thank you for your time.
It was weekend, so I didn't reply. Just finished Avengers Infinity War, greatest movie of 2018.
Anyway back to the question, just to answer chicopee, this is a reverse flame fire tube boiler. I think i didn't sketch the overall of the system. You can check it out in...
Hello ladies and gentlemen,
My objective is to find the tube exit gas temperature in fire tube boiler. I know the rate of heat transfer, Q=m.c.delta T, should be equal between gas and water side. Anyway, I have work out the analysis as attached. However, I just cannot seem to get the final...