Applicable for API pumps. Qualifying nozzle loads and movements for imposed piping loads using CAESAR.The maximum size covered is up to 16',selecting allowable based on nozzle size and rating for150# are accessible,see table-5 of API-610,And choose for the orientation of nozzle inline with your...
criteria used for nozzle load is based on movement( basically .0050 to .0100 depending on the size of the pump.) over the coupling end of shaft due to forces Fx, Fy, Fz, Fr .
These forces are taken into consideration for checking movement of the entire assembly when load is put on,Movement of...