  1. MRLatLSC

    Concrete foundations and HDPE pipe

    Thanks for the info all. I did find PPI's Handbook of PE pipe but did not see anything expressly prohibiting nor giving the practice the thumbs up. Unfortunately the client has shelved the project for now and stopped all contract work on it! I appreciate the swift feedback from everyone.
  2. MRLatLSC

    Concrete foundations and HDPE pipe

    Can anyone recommend good sources of information regarding codes or standards for HDPE pipe and concrete foundations? A current project of mine involves piping fluid below grade from an outdoor storage tank and coming above grade indoors. The client has requested the use of HDPE pipe and wants...
  3. MRLatLSC

    Vent size on atmospheric tanks

    I am currently trying to determine the adequacy of an existing vent in a tank for a pressure relief scenario. Is there a particular equation or calculation to verify what size vent is needed? I have looked through API 2000, NFPA 30 and Crane TP 410 (the most difficult to interpret) and thus...
  4. MRLatLSC

    How to calculate fluid velocity at multiple points in a piping system

    Thank you for the insight. I will consult with the operations crew. I am not sure if it is a client requirement or what? I have recently been added to this project group and don't have the full details.
  5. MRLatLSC

    How to calculate fluid velocity at multiple points in a piping system

    The reason I am doing this is to get an idea of what velocities will be seen at some level flow sensors installed at these vent lines. I am under the impression that this will aid the procurement and electrical folks in determining what flow switches they need. You are correct-I did not draw...
  6. MRLatLSC

    How to calculate fluid velocity at multiple points in a piping system

    On my first attempt I did get a velocity that was way too high (around 600 m/s!) and knew I did something wrong or made a faulty assumption. A second attempt provided more believable results but I am still concerned about some of my assumptions and the way I simplified things on my model. I...
  7. MRLatLSC

    How to calculate fluid velocity at multiple points in a piping system

    Is there a more convenient way to attach a file or sketch rather than using html format?
  8. MRLatLSC

    How to calculate fluid velocity at multiple points in a piping system

    I have a piping system consisting of a pig launcher with a fill line flowing into it and a vent line flowing out of it. The 2" diameter fill line pulls crude off a mainline operating at 1017.1 psi and a flow rate of 633 Kbpd. The crude flows from the mainline to a pig launcher via the fill...