My mistake. Discharge pressure will likely decrease unless you have a pressure controlling device, but overall differential pressure across your compressor will increase.
kloroform,
First off, remember that although the unit SCFD seems to convey a volume flow, this unit doesn't actually define a volume flow, but rather a certain amount of molecules per unit time. Keep this in mind through the following explanation.
First of all, a common misconception with...