  1. paulinaote

    HYSYS Topping unit distillation crude

    Hello Everyone: According to their work experiences, what are the requirements of REDUCED CRUDE to be treated in a SIMPLE VACCUM FLASHER?? (heavy metals,sulfur,etc etc etc...any requirement that you know. Thank you very much for your attention
  2. paulinaote

    HYSYS Topping unit distillation crude

    Hello!!....again. I´m tunning my simulation and I originated a question. Is there a problem if the number of theoretical trays exceeds the number of actual tray?? Regards
  3. paulinaote

    HYSYS Topping unit distillation crude

    Thanks, can you send me esta paper via e-mail, there a problem with the proxy. paulinabarrientos.s@gmail.com
  4. paulinaote

    HYSYS Topping unit distillation crude

    PROPERTIEShttp://files.engineering.com/getfile.aspx?folder=243c9293-2182-4bca-9ff8-48b2fce40aa8&file=properties.jpg
  5. paulinaote

    HYSYS Topping unit distillation crude

    PROPERTIES: NAFTA KEROSENE DIESEL 63.36 °API 47 °API 38.08 °API ASTM D86 °C Flash point 41°C Flash Point 79 °C 0% 38 Freeze Point -51 °C Pour Point -6 °C 10% 69 ASTM D86 °C ASTM D86 °C 50% 101 0% 147 0% 179.3 90% 129 10% 165 10% 225 100% 161 50% 192 50% 274 90% 230 90% 316.3 100% 256 100% 340...
  6. paulinaote

    HYSYS Topping unit distillation crude

    EXCELhttp://files.engineering.com/getfile.aspx?folder=d742e422-c0fa-4b47-a1c7-e04964000243&file=Datos_de_Proceso_Refinería_Gregorio_ABRIL_2015..xlsx
  7. paulinaote

    HYSYS Topping unit distillation crude

    Many many thank you very much for your time. Consider a friend in Patagonia. I worked all day in the simulation,followind your advice. Finally arrive at more realistic results (envelope phase and operating parameters). These are the actual data: PRODUCTION m3/d NAFTA: 570 KERO: 450 DIESEL...
  8. paulinaote

    HYSYS Topping unit distillation crude

    comparison of curves D86http://files.engineering.com/getfile.aspx?folder=d8dbf410-5dd4-45c3-a079-427a68a85c9b&file=D86_Productos_Comparacion_HYSYS-LAB.SIM16.xlsx
  9. paulinaote

    HYSYS Topping unit distillation crude

    Master phase envelopehttp://files.engineering.com/getfile.aspx?folder=c4df7e96-8251-45e2-a1ef-7a36ee24e858&file=Master_phase_envelope_SIM_16.jpg
  10. paulinaote

    HYSYS Topping unit distillation crude

    I did the simulation again with a feed: CRUDO X: 50% date: TBP - API - Viscosity CRUDO Y: 50%: TBP - API - Viscosity a total 2650 m3/d (april average). The result is far from the actual (Cold properties product - T Condenser - T tope - T bottom - D86 HYSYS v.s Lab) Which is the reason this BIG...
  11. paulinaote

    HYSYS Topping unit distillation crude

    you mean the green line, right? This should not be a single straight linehttp://files.engineering.com/getfile.aspx?folder=91a9b360-9f07-4a04-8ead-d4f8cb1c5212&file=master_phase_envelope.jpg
  12. paulinaote

    HYSYS Topping unit distillation crude

    OK.. will try again tested mixtures. I shall guide from phase evelope utility as you mention. Has you a reference picture as it should be that curve? Regards
  13. paulinaote

    HYSYS Topping unit distillation crude

    Not for iterating...I've tried in many many many ways, but there is something I'm not seeing. H E L P http://files.engineering.com/getfile.aspx?folder=575fde61-f777-4ae1-8892-a092d42b526d&file=SIM_15.4.rar
  14. paulinaote

    HYSYS Topping unit distillation crude

    Thanks for the advice, I think it's exactly the mistake I make. Then keep the characterization as is.
  15. paulinaote

    HYSYS Topping unit distillation crude

    Because, feedin to the plant is a mix of many crude in different percentage. Only I have the characterization of two raw(I could not get more because they must ask at an external laboratory). These crudes are: CRUDO X CRUDO Y CRUDO X, its 35% of feed and CRUDO Y its 1% of feed. Of these crude...
  16. paulinaote

    HYSYS Topping unit distillation crude

    P/A zone its nutter rings
  17. paulinaote

    HYSYS Topping unit distillation crude

    Thank you very much for your support, needed advice from someone with experience. I realized my mistake.'ll add the dishes in the areas mentioned. Many thank you very much.....hopefully converges me
  18. paulinaote

    HYSYS Topping unit distillation crude

    Real Trays: 24 Reflux Return: 1 Kero Draw: 7 Diesel Draw: low the Packing Bed, 17 tray. Zona Flash: Mellapack, (18-19-20) Crude Feed: up tray 21 (20) Stripping Reduced Crude: 21-22-23-24 (page 1)...
  19. paulinaote

    HYSYS Topping unit distillation crude

    I'll add another theoretical plate above de flash zone according to your advice...hopefully converges me