Thanks for feedback again. There are valuable information provided.
@georgeverghese
RD has been chosen as Client standard requires for that type of service. I have roughly checked unavoidable tolerances with maximum expected operating pressure and in my eyes sufficient...
Thanks for feedback!
@EmmanuelTop
Burst pressure is set in gauge units, not differential units. - that was exactly my question - how to mark RD burst pressure correctly - thanks!
@georgeverghese
RD is installed on low pressure side of HX (shell). This is gas-gas service. Is there any...
@EmmanuelTop
Thanks for sharing. However, I have read that comprehensive summary before placing my question here.
Assuming design pressure of the vessel protected is equal to MAWP equal to 100 psig, what should be burst pressure of rupture disc - 95 psi or 95 psi[g]?
Refer to Figure 1B here...
Dear forum members,
recently I have encountered the following issue when specify rupture discs - seems to be trivial, but the longer
I think the more questions are coming up:
Rupture disc is installed at the low pressure side of heat exchanger. Rupture disc outlet is connected to the flare...