Thanks Pat, appreciate your reply.
I think you are refering to Heat defelection or HDT (i.e. HDT@ 1.80MPa (pls correct me). There is another temp which say Max Operating temp which confuses me. For example on
PA6-30GF HDT @1.80MPa temp is 205C then the data on Max Operating temp is only 80C...
Guys I am new on this forum, I wonder if someone can help me.
I am trying to solve a design problem of our Plastic propeller fan, the fan tends to creep/distorted when subjected to higher temp (60 C) that leads to broken blades. It originally uses an ABS20GF, I tried to use
PP30GF but result...
CB1/Waunakee,
Thanks a lot for your inputs, I think Wanaukee is right
as Centrif's can produce higher pressure on the air
discharge side while Prop's can cannot. On the other hand CB
point is also correct, when a strong wind blows directly to the unit that same air will cools down condenser...
Hi Fan expert,
Need your help to select a better AMD/Fan type that could overcome high wind (or worst case: typhoon) on a High rise building for an ACCU units on a horizontal air throw application.