Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: pkg80
  • Order by date
  1. pkg80

    Cavitation in mutistage pump

    Hello terrorist First , you should 1st confirm that this is cavitation ,you are judging now only by sound, at least you can perform the vibration test and be sure that there is cavitation in pump.
  2. pkg80

    Motor end /axial play ????

    hello Artisi /1gibson Thanks for reply This motor drives the pump which is using for propane transfer. Motor power =200HP RPM=1800 Motor bearing : Antifriction bearing Arrangement of equipment : Horizontal I want to know the general thumb rule or whatever the method to decide the best...
  3. pkg80

    Motor end /axial play ????

    hello can any one suggest the minimum and maximum axial/end play for the induction motor with antifriction bearing. If axial play is more what may be the bad effect on the equipment ?
  4. pkg80

    Out board bearing lube oil being dis coloured

    hello all We have a 4 stage Centrifugal pump recently overhauled. After overhauling there was some abnormal noise from OB bearing ,We had changed that bearing(ANGULAR CONTACT BALL BEARING) ,now oil is being discolored in 3-4 days of running of pump. We have flushed and refill two times but...
  5. pkg80

    Reliability group question

    I think this is not standard to use vibration measurement tools for shim adjustment in running condition . Yes, it can be used to find the soft foot during running the equipment. once you find out the problem of soft foot you can stop the equipment and correct it by using the dial indicator.
  6. pkg80

    pump taking high current

    i have here attached pump drawing.http://files.engineering.com/getfile.aspx?folder=3ed5314d-6b39-4d9a-831a-927fe475db3e&file=IMAG0036.jpg
  7. pkg80

    pump taking high current

    Hello georgeverghese will provide you the drawing .shaft seal is working fine and have plan 13 and 76.No barrier fluid.
  8. pkg80

    pump taking high current

    hello georgeverghese Thanks for reply Yes you are right ,The process fluid is ethane with sp. gravity 0.435. Motor voltage is 4000V. It might be problem with intermediate shaft sleeve but I think it should reflect in vibration and vibration is normal. also we can not open the pump without...
  9. pkg80

    pump taking high current

    hello JJPellin pump is equipped with 435kw motor , pumps running with following data for pump A Differential pressure is 117psi for pump C Differential pressure is 116psi Total flow for both pump is 13805BPH
  10. pkg80

    pump taking high current

    hello EdStainless suction / discharge tapping on the same distance from the piping for all pumps and it is just before and after the pump. Motor is identical in all pumps.
  11. pkg80

    pump taking high current

    hello Artisi yes ,this is running with overcurrent 76-80 amps (More than full load current 75 amps ) always and sister pump with 65-69amps ,it not like spike.This is vertically suspended (V3) centrifugal pump. What do you mean by running clearance ? phase current already checked and its nearly...
  12. pkg80

    pump taking high current

    Hello jjpellin /LITTLEINCH Thanks for reply This pump has closed impeller and we have already checked all 3 phase current and t is like 76 78 & 76 for one pump and 66 67 & 68 for another pump. These pumps have not any minimum flow lines individually. is it good idea to check motor by solo...
  13. pkg80

    pump taking high current

    i have attached here pump curve.http://files.engineering.com/getfile.aspx?folder=ce111779-a718-43c7-9f7c-c038c678e6a2&file=Scan_20160209_121056_(1).pdf
  14. pkg80

    pump taking high current

    hello all thanks for your interest and reply I have seen the all pump curves supplied by the vendor and it is similar for all three pumps .I will provide to you pump curve. Here difference in ampere is by 8-10 amps in both pumps which delivering similar head in parallel operation. As I said...
  15. pkg80

    pump taking high current

    thanks littleinch for ur reply... As I said these pumps are identical and generating same head (same discharge pressure)with same suction pressure.They have common suction and discharge piing. usually two pumps run parallel.
  16. pkg80

    pump taking high current

    hello we have three similar vertical pump in parallel operation with full load current of 75amps. One pump is taking current more than full load current 75amps. It takes 76-80amps. Others pumps takes 65-69amps @same time for same parameter.generally two pumps always in operation. I have...