Hello,
I'm having the same problem regarding to the lack of loadcase combination for the hydrostatic test condition for the plastic collapse evaluation with an elastic analysis in table 5.3.
¿Would it be appropiate if I use Ps (according to table 5.2 - Static head from liquid or bulk materials)...