Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations SDETERS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: TheDW
  • Order by date
  1. TheDW

    Digitally sign Structural drawing

    I've got a 'Identrust Global Common Basic Assurance' certificate and it was $81 last year. Haven't gotten around to renewing so I am not sure if they have raised the cost
  2. TheDW

    Digitally sign Structural drawing

    I went with identrust after reading some threads on here. They've got a few different levels of verification/cost but if you tell them you're just looking for the Florida PE licensure verification, someone pointed me to exactly what i needed
  3. TheDW

    Digitally sign Structural drawing

    I'm with you. For my CAD seal I just modified the text of the cad file someone else had been using for 20 years It would not take more than 5 minutes to draw a stamp in CAD, no $20 needed. For such a red 'party of small government' state, Florida's government is way more involved than is...
  4. TheDW

    Net negative wind pressure on MWFRS sloped roof?

    I prefer chapter 27 where they have the specific alt load case with the smaller positive pressure on the windward side
  5. TheDW

    Hand framed rafter with ridge beam - dropped ceiling joist.

    Framers in my area would want to platform frame it...stop the studs with top plates at the ceiling height, and build a knee wall on top of the ceiling joists.
  6. TheDW

    Does the IBC/IRC confirm the requirement for diaphragm continuity through detailing?

    For sure. I work a lot in SDC D so the IRC backs us up on that front fortunately. But, the way I see it going in SDC A,B,C, is that a contractor ignores the blocking in our drawings, and when we push for it they could be savvy enough to be in the owners ear citing a specific code section...
  7. TheDW

    Does the IBC/IRC confirm the requirement for diaphragm continuity through detailing?

    I share your frustration in this area. R602.10.8.2 goes as far as saying that heel heights of less than 9.25" in SDC A,B,C specifically do not require blocking. I've also seen a lot of these rationalized using the hold down hardware to resist overturning but I am not a fan. If a shear wall is...
  8. TheDW

    HSS column design with shear plate connection

    '...must be considered in the column design' does not mean 'must apply a moment at the top of the column'. Rationalizing whether the column actually sees and needs to be designed for moment is 'considering the eccentricity in the design' It looks like lexpatries article references the AISC...
  9. TheDW

    Residential Joists Drafting Standard

    I don't think I've ever had someone reach out deliberately with the question either but I occasionally get truss shops where it was obviously not understood, and have had to review already constructed stick framing occasionally that was also installed by someone that did not understand. I...
  10. TheDW

    Residential Joists Drafting Standard

    The span direction is obvious in the OP due to the layout, but if it were a square bay with the two arrow types I honestly wouldn't be 100% confident in which direction is intended, even with the legend. I would probably have to dig through the plan to find an obvious location like pictured to...
  11. TheDW

    Residential Joists Drafting Standard

    I would also in a perfect world prefer to show every joist.
  12. TheDW

    Residential Joists Drafting Standard

    Its not really relevant but the unpictured joists are in the kitchen with granite countertops all over the place, so they have a tighter spacing. I like the jog to differentiate between the 'joist' line which is always straight, and its location arrows...I feel like 2 straight lines could have...
  13. TheDW

    Residential Joists Drafting Standard

    I'm in SC and I do it like this, and include this legend on framing plans. I've seen different arrows mean different things on so many plans. Some with just your 'harpoon' and no 'extents' arrow, and I'll have no clue which way they're supposed to be going, so I get why contractors would get...
  14. TheDW

    TJI Floor Joists as Floor Diaphragm @ Basement Wall - Compression Issue?

    If there is a US version of this bulletin, I can't find it, so here you go, you may find this more helpful than the roof structure bulletin : https://www.weyerhaeuser.com/woodproducts/document-library/document_library_detail/tb-155/#download I think the shear transfer you're looking at is the...
  15. TheDW

    TJI Floor Joists as Floor Diaphragm @ Basement Wall - Compression Issue?

    I think you could add blocking etc to be reasonably confident in the TJI's transferring load to the diaphragm, then you just have to make sure the load has somewhere to go from the diaphragm. I'll insist that the wall be raised up flush with the t/joists, and the joists attached to a ledger. I...
  16. TheDW

    Billing Rates

    All of the above, we're very small with 2 principals functioning as PM's and a handful of EITs, everybody is $250/hr. We've talked about breaking it up but haven't gotten around to it.
  17. TheDW

    Billing Rates

    Sounds like I need to raise my lump sum fees a bit then !
  18. TheDW

    Billing Rates

    Is that working well? The older guy in our office says decades back, they would price everything on 0.5% (.005) of estimated construction cost with a ballpark $/sf figure. I know material costs have come back down but that rule of thumb would still have us almost doubling our fees on most...
  19. TheDW

    Billing Rates

    We were at $200/hr for a long time (at least 5 years) and bumped it up to $250 maybe 2 years ago Our workflow is set up well so that our lump sum projects will usually put us over our hourly rate Like jerseyshore we don't often do hourly work, it mostly comes into play with anything...
  20. TheDW

    Billing Rates

    We are at $250/hr in SC doing mostly residential work I worked at a big firm ~6 years ago where principals were billing at $300/hr Site visits + reports are $600, more if its an issue that requires drawings or more in depth investigation. Most of our projects range from $1200-$8000 It is...

Part and Inventory Search